Suppr超能文献

四种市售临时材料制作的全冠边缘适合性的比较评价:一项体外研究。

A comparative evaluation of the marginal accuracy of crowns fabricated from four commercially available provisional materials: An in vitro study.

作者信息

Amin Bhavya Mohandas, Aras Meena Ajay, Chitre Vidya

机构信息

Department of Prosthodontics, Goa Dental College, Bambolim, Goa, India.

出版信息

Contemp Clin Dent. 2015 Apr-Jun;6(2):161-5. doi: 10.4103/0976-237X.156035.

Abstract

PURPOSE

The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min).

MATERIALS AND METHODS

A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min.

OBSERVATIONS AND RESULTS

Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star.

CONCLUSION

The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83-128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns.

摘要

目的

本体外研究旨在评估并比较四种市售临时材料(Protemp 4、Luxatemp Star、Visalys Temp以及DPI牙模粉和液体)在两个时间间隔(10分钟和30分钟)时的初始边缘精度。

材料与方法

使用一个定制的含两个可互换代型的不锈钢母模来制作临时冠。制作了40个冠(n = 10),每个冠在体视显微镜下进行评估。记录并比较自混合开始10分钟时以及之后30分钟时的垂直边缘差异。

观察结果

Protemp 4在10分钟时显示出最小的垂直边缘差异(71.59微米),其次是Luxatemp Star(91.93微米)。DPI显示边缘差异为95.94微米,而Visalys Temp冠的垂直边缘差异为106.81微米。Protemp 4和Visalys Temp的边缘差异值存在显著差异。在30分钟时,Protemp 4冠(83.11微米)与Visalys Temp冠(128.97微米)之间以及Protemp 4和DPI之间(118.88微米)的边缘差异存在显著差异。Protemp 4和Luxatemp Star之间未观察到显著差异。

结论

由这四种市售临时材料制作的临时冠的垂直边缘差异在制作后立即(自混合开始10分钟时)为71至106微米,到(自混合开始30分钟时)为83 - 128微米。混合后经过的时间对冠的边缘精度有显著影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e25f/4456735/975809a93a13/CCD-6-161-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验