在晶状体拉伸器中调节过程中晶状体体积的测量。

Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

作者信息

Marussich Lauren, Manns Fabrice, Nankivil Derek, Maceo Heilman Bianca, Yao Yue, Arrieta-Quintero Esdras, Ho Arthur, Augusteyn Robert, Parel Jean-Marie

机构信息

Ophthalmic Biophysics Center Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States 2Biomedical Optics and Laser Laboratory, Department of Biomedical Engineering, University of Miami, College of Engineeri.

Ophthalmic Biophysics Center Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States.

出版信息

Invest Ophthalmol Vis Sci. 2015 Jul;56(8):4239-48. doi: 10.1167/iovs.15-17050.

Abstract

PURPOSE

To determine if the lens volume changes during accommodation.

METHODS

The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated.

RESULTS

The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g.

CONCLUSIONS

Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

摘要

目的

确定晶状体在调节过程中体积是否发生变化。

方法

本研究使用了在36只食蟹猴晶状体上获取的数据,这些晶状体以逐步拉伸的方式进行伸展以模拟非调节状态。在每个步骤中,测量拉伸力和屈光力,并使用光学相干断层扫描系统获取晶状体的横截面图像。对图像进行屈光畸变校正,并假设旋转对称计算晶状体体积。计算晶状体体积的平均变化,并量化体积变化与屈光力变化之间以及体积变化与拉伸力之间的关系。计算体积-屈光力和体积-力曲线的线性回归。

结果

未拉伸(调节)状态下的平均(±标准差)体积为97±8mm³。平均而言,随着拉伸,测量的晶状体体积有微小但具有统计学意义(P = 0.002)的增加。晶状体体积的平均变化为+0.8±1.3mm³。平均体积-屈光力和体积-负荷斜率分别为-0.018±0.058mm³/D和+0.16±0.40mm³/g。

结论

晶状体体积在调节过程中实际上保持恒定,平均变化小于1%。这一结果支持了这样一种假设,即晶状体形状随调节的变化伴随着囊袋内组织的重新分布,而晶状体内容物没有明显压缩,也没有通过囊膜的液体交换。

相似文献

引用本文的文献

2
On the Cranial Nerves.论颅神经。
NeuroSci. 2023 Dec 28;5(1):8-38. doi: 10.3390/neurosci5010002. eCollection 2024 Mar.

本文引用的文献

2
OCT 3-D surface topography of isolated human crystalline lenses.离体人晶状体的光学相干断层扫描三维表面形貌
Biomed Opt Express. 2014 Sep 11;5(10):3547-61. doi: 10.1364/BOE.5.003547. eCollection 2014 Oct 1.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验