Suppr超能文献

Histopathologic findings of perforated corneas due to ferric ion infiltration.

作者信息

Kato Kumiko, Hirano Koji, Takashima Yuko, Sakamoto Satoe, Kondo Mineo

机构信息

Department of Ophthalmology, Mie University School of Medicine, Tsu City, Japan.

Department of Ophthalmology, Ban Buntane Houtokukai Hospital, School of Medicine, Fujita Health University, Nagoya, Japan.

出版信息

Can J Ophthalmol. 2015 Aug;50(4):322-7. doi: 10.1016/j.jcjo.2015.05.011.

Abstract

OBJECTIVE

To report the histopathologic findings of 3 corneal buttons incised from 2 patients during penetrating keratoplasty (PKP) because of corneal perforation due to corneal siderosis.

METHODS

Three eyes of 2 patients had accidental trauma to the corneas caused by iron fragments; the injuries were initially treated conservatively with antibiotics and therapeutic soft contact lenses. However, the corneal stroma melted and perforated, necessitating corneal transplantation. The corneal buttons removed during PKP were examined histopathologically, and the findings were compared with the slit-lamp biomicroscopic and anterior segment optical coherence tomographic (AS-OCT) findings.

RESULTS

Slit-lamp examinations showed that the corneal epithelium was hyperplasic around the area of perforation in 2 eyes 1 month after the injury. Wide areas of the stroma had melted, and the corneas were perforated. The corneal epithelium was atrophic in the perforated corneas 4 months after injury. Histopathologically, the corneal stroma and Descemet's membrane were stained by Prussian blue, suggesting that the ferric ions had penetrated deeper than expected by the slit-lamp examinations. The areas of Prussian blue staining corresponded well with the areas altered in the AS-OCT images.

CONCLUSIONS

Ferric ions penetrate much deeper into the cornea than estimated by slit-lamp biomicroscopy. The ferric ions can induce stromal melting that can lead to corneal perforation. We conclude that (i) the ferric ion-infiltrated areas can be estimated in the AS-OCT images and (ii) extensive corneal abrasion should be performed to prevent corneal melting and perforation.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验