Suppr超能文献

免疫细胞中比色法细胞增殖检测的比较研究

A comparative study of colorimetric cell proliferation assays in immune cells.

作者信息

Koyanagi Madoka, Kawakabe So, Arimura Yutaka

机构信息

Host Defense for Animals, School of Animal Science, Nippon Veterinary and Life Science University, 1-7-1 Kyonan, Musashino, Tokyo, 180-8602, Japan.

出版信息

Cytotechnology. 2016 Aug;68(4):1489-98. doi: 10.1007/s10616-015-9909-2. Epub 2015 Aug 18.

Abstract

Cell proliferation assays are basic and essential techniques for assessing cellular function. Various colorimetric assays, such as MTT-, WST-1-, and resazurin-based assays, are available; however, studies directly comparing the suitability of each method for immune cell proliferation are scarce. Thus, we aimed to determine the best reagent and its optimal conditions based on variables such as cell number range, stimulation dose, kinetics, and compatibility with the cell division assay using CFSE fluorescence dye which is able to directly monitor divided cells by flow cytometry. In the absence of stimulation, MTT solubilized with SDS (MTT-SDS) and resazurin appeared to accurately reflect the cell numbers in a linear fashion. On the other hand, WST-1 exhibited a higher stimulation index following strong stimulation, whereas MTT-SDS and resazurin exhibited a better sensitivity to weak stimulation. A longer duration for stimulation did not necessarily increase sensitivity. CFSE staining revealed incremental cell division in response to anti-CD3 antibody stimulation in a dose-dependent manner. The cell numbers indirectly estimated from cell division profiles were consistent with the dose-response curve in the absorbance of MTT-SDS and resazurin. The absorbance does not increase before cell division, irrespective of T cell activation status, suggesting that these reagents reflect the cell number but not the cellular volume. Collectively, resazurin and MTT-SDS seem to be more reliable than others, and thus appear applicable in various conditions for the immune cell experiments.

摘要

细胞增殖测定是评估细胞功能的基本且重要的技术。有多种比色测定法可供选择,例如基于MTT、WST-1和刃天青的测定法;然而,直接比较每种方法对免疫细胞增殖适用性的研究却很匮乏。因此,我们旨在根据细胞数量范围、刺激剂量、动力学以及与使用CFSE荧光染料的细胞分裂测定法的兼容性等变量,确定最佳试剂及其最佳条件,CFSE荧光染料能够通过流式细胞术直接监测分裂细胞。在无刺激的情况下,用SDS溶解的MTT(MTT-SDS)和刃天青似乎能以线性方式准确反映细胞数量。另一方面,WST-1在强刺激后表现出较高的刺激指数,而MTT-SDS和刃天青对弱刺激表现出更好的敏感性。较长的刺激持续时间不一定会增加敏感性。CFSE染色显示,抗CD3抗体刺激后细胞分裂呈剂量依赖性增加。从细胞分裂图谱间接估计的细胞数量与MTT-SDS和刃天青吸光度的剂量反应曲线一致。无论T细胞激活状态如何,在细胞分裂前吸光度都不会增加,这表明这些试剂反映的是细胞数量而非细胞体积。总体而言,刃天青和MTT-SDS似乎比其他试剂更可靠,因此似乎适用于免疫细胞实验的各种条件。

相似文献

1

引用本文的文献

2
A New Light-Sensor System Affecting Cancer Cell Fate.一种影响癌细胞命运的新型光传感器系统。
Biomater Res. 2025 Mar 5;29:0157. doi: 10.34133/bmr.0157. eCollection 2025.

本文引用的文献

6
Akt is a neutral amplifier for Th cell differentiation.
J Biol Chem. 2004 Mar 19;279(12):11408-16. doi: 10.1074/jbc.M309063200. Epub 2004 Jan 5.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验