Suppr超能文献

3T下非增强型速度选择性外周血管造影中图像伪影的识别与减少

Identification and reduction of image artifacts in non-contrast-enhanced velocity-selective peripheral angiography at 3T.

作者信息

Shin Taehoon, Qin Qin, Park Jang-Yeon, Crawford Robert S, Rajagopalan Sanjay

机构信息

Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, Maryland, USA.

The Russel H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

出版信息

Magn Reson Med. 2016 Aug;76(2):466-77. doi: 10.1002/mrm.25870. Epub 2015 Aug 26.

Abstract

PURPOSE

To identify and reduce image artifacts in non-contrast-enhanced velocity-selective (VS) magnetization-prepared peripheral MR angiography (MRA) at 3T.

METHODS

To avoid signal loss in the arteries, double and quadruple refocused VS excitation pulse sequences were designed that were robust to a wide range of B0 and B1 offset. To suppress stripe artifact and background signal variation, we successively applied two VS preparations with excitation profiles shifted by half the period of the stripes. VS-MRA using single, double, and quadruple refocused VS preparations was tested in healthy subjects and a patient.

RESULTS

In the regions of large B0 and B1 offsets, arterial signal loss was yielded by single refocused VS preparation, but was avoided with double or quadruple refocused preparations. Compared with single VS preparation, the two consecutive preparations with shifted excitation profiles substantially reduced the stripe artifact and background signal variation, as demonstrated by increased mean and decreased standard deviation of relative contrast-to-noise ratio. The proposed VS-MRA identified multilevel disease in the femoral arteries of the patient, as validated by digital subtraction angiography.

CONCLUSION

Two multiple refocused VS magnetization preparations with shifted excitation profiles yield artifact-free peripheral angiograms at 3T. Magn Reson Med 76:466-477, 2016. © 2015 Wiley Periodicals, Inc.

摘要

目的

识别并减少3T场强下非增强速度选择(VS)磁化准备外周磁共振血管造影(MRA)中的图像伪影。

方法

为避免动脉信号丢失,设计了双重和四重重聚焦VS激发脉冲序列,该序列对广泛的B0和B1偏移具有鲁棒性。为抑制条纹伪影和背景信号变化,我们相继应用了两种VS准备,其激发轮廓偏移条纹周期的一半。在健康受试者和一名患者中测试了使用单重、双重和四重重聚焦VS准备的VS-MRA。

结果

在B0和B1偏移较大的区域,单重重聚焦VS准备会导致动脉信号丢失,但双重或四重重聚焦准备可避免这种情况。与单重VS准备相比,激发轮廓偏移的两个连续准备显著减少了条纹伪影和背景信号变化,相对对比噪声比的平均值增加和标准差降低证明了这一点。所提出的VS-MRA识别出了患者股动脉的多级病变,数字减影血管造影验证了这一点。

结论

两种激发轮廓偏移的多重重聚焦VS磁化准备在3T场强下可产生无伪影的外周血管造影。《磁共振医学》76:466 - 477, 2016。© 2015威利期刊公司。