Measured (TGVm) and predicted (TGVp) thoracic gas volumes from the BOD POD were compared in 33 lean, university athletes. On average, TGVp (3.529 L) was not significantly different (p = 0.343) from TGVm (3.628 L); however, there was a bias (r = -0.703, p < 0.001). The difference in the percentage of body fat (BF) was within ±2% BF for 76% of the sample, but athletes at the extremes of height should have TGV measured.
在33名体型偏瘦的大学生运动员中,对通过BOD POD测量得到的胸廓气体容积(TGVm)和预测的胸廓气体容积(TGVp)进行了比较。平均而言,TGVp(3.529升)与TGVm(3.628升)无显著差异(p = 0.343);然而,存在偏差(r = -0.703,p < 0.001)。76%的样本中体脂百分比(BF)差异在±2% BF以内,但身高处于极端值的运动员应测量TGV。