Suppr超能文献

The effect of inotropic dose of dobutamine during reperfusion on myocardial infarct size.

作者信息

Ooiwa H, Miura T, Downey J M, Matsuki T, Shizukuda Y, Adachi T, Tsuchida A, Iwamoto T, Ogawa T, Iimura O

机构信息

Second Department of Internal Medicine, Sapporo Medical College, Japan.

出版信息

Jpn Circ J. 1989 Dec;53(12):1511-20. doi: 10.1253/jcj.53.1511.

Abstract

We examined whether dobutamine infusion during reperfusion modifies myocardial infarct size in a rabbit ischemia-reperfusion model. Prior to the infarct size study, the hemodynamic response to dobutamine 5, 10, and 15 micrograms/kg/min i.v. was evaluated in the rabbit model. Ten micrograms/kg/min of dobutamine increased the left ventricular dp/dt max by 34.0 +/- 4.9% (n = 7) and the myocardial blood flow from 0.86 +/- 0.16 to 2.19 +/- 0.57 ml/min/g without change in the collateral blood flow (n = 4). The heart rate, systolic and diastolic blood pressures were elevated by only 4.7 +/- 1.0%, 9.4 +/- 3.0%, and 8.0 +/- 3.7%, respectively (n = 7). In the infarct size study, a coronary branch was occluded for 30 min and then reperfused. Seventy-two hours after reperfusion, the myocardium supplied by the occluded artery (area at risk, AAR) and the infarcted area were determined by fluorescent particles and histology (hematoxylin-eosin and modified Mallory's staining), respectively. In the dobutamine treated group (DB group), 10 micrograms/kg/min of dobutamine were infused for 30 min starting immediately after reperfusion, and a comparable volume of saline was infused in the control group. Hemodynamic parameters and the size of AAR were comparable in the control and DB groups. Myocardial infarct size, expressed as the percentage of AAR, was 45.1 +/- 3.9% in the control (n = 11) and 40.2 +/- 2.4% in the DB group (n = 10), which was not significantly different. These findings indicated that the inotropic dose of dobutamine administered during reperfusion did not cause myocardial necrosis by disturbing the recovery process of the myocardium from ischemic injury.

摘要

相似文献

1
The effect of inotropic dose of dobutamine during reperfusion on myocardial infarct size.
Jpn Circ J. 1989 Dec;53(12):1511-20. doi: 10.1253/jcj.53.1511.
2
Cardiac protection by ischaemic preconditioning is not mediated by myocardial stunning.
Cardiovasc Res. 1993 Apr;27(4):585-92. doi: 10.1093/cvr/27.4.585.
9
Dobutamine modifies myocardial infarct size through supply-demand balance.
Am J Physiol. 1988 May;254(5 Pt 2):H855-61. doi: 10.1152/ajpheart.1988.254.5.H855.
10
Progression of myocardial infarction in a collateral flow deficient species.
Jpn Heart J. 1989 Sep;30(5):695-708. doi: 10.1536/ihj.30.695.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验