IMAGES, Université De Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan Cedex 66860, France.
IMAGES, Université De Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan Cedex 66860, France; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology (CIIT), Lahore 54000, Pakistan.
Anal Chim Acta. 2015 Aug 19;889:106-12. doi: 10.1016/j.aca.2015.06.052. Epub 2015 Aug 10.
Contamination of food by mycotoxin occurs in minute/trace quantities. Nearly 92.5% of the cocoa samples present Ochratoxin A (OTA) levels at trace quantity. Hence, there is a necessity for a highly sensitive and selective device that can detect and quantify these organic toxins in various matrices such as cocoa beans. This work reports for the first time, a facile and label-free electrochemical impedimetric aptasensor for rapid detection and quantitation of OTA in cocoa beans. The developed aptasensor was constructed based on the diazonium-coupling reaction mechanism for the immobilization of anti-OTA-aptamer on screen printed carbon electrodes (SPCEs). The aptasensor exhibited a very good limit of detection (LOD) as low as 0.15 ng/mL, with added advantages of good selectivity and reproducibility. The increase in electron transfer resistance was linearly proportional to the OTA concentration in the range 0.15-2.5 ng/mL, with an acceptable recovery percentage (91-95%, RSD = 4.8%) obtained in cocoa samples. This work can facilitate a general model for the detection of OTA in cocoa beans based on the impedimetric aptasensor. The analysis can be performed onsite with pre-constructed and aptamer modified electrodes employing a portable EIS set up.
食品中的真菌毒素污染以痕量/微量的形式存在。近 92.5%的可可样品中存在痕量的赭曲霉毒素 A(OTA)。因此,需要一种高度敏感和选择性的装置,可以检测和定量各种基质(如可可豆)中的这些有机毒素。这项工作首次报道了一种简便且无需标记的电化学适体传感器,用于快速检测和定量可可豆中的 OTA。所开发的适体传感器基于重氮偶联反应机制,用于将抗 OTA-适体固定在丝网印刷碳电极(SPCE)上。该适体传感器的检测限(LOD)非常低,低至 0.15 ng/mL,具有良好的选择性和重现性。在 0.15-2.5 ng/mL 的范围内,电子转移电阻的增加与 OTA 浓度呈线性比例关系,在可可样品中获得了可接受的回收率(91-95%,RSD=4.8%)。这项工作可以为基于电化学适体传感器的可可豆中 OTA 的检测提供一个通用模型。可以使用预构建的和带有适体修饰的电极在现场进行分析,使用便携式 EIS 设备进行。