Suppr超能文献

舟状骨双侧对称性的三维评估:一项解剖学研究

Three-Dimensional Assessment of Bilateral Symmetry of the Scaphoid: An Anatomic Study.

作者信息

ten Berg Paul W L, Dobbe Johannes G G, Strackee Simon D, Streekstra Geert J

机构信息

Department of Plastic, Reconstructive, and Hand Surgery, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, Netherlands.

Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, Netherlands.

出版信息

Biomed Res Int. 2015;2015:547250. doi: 10.1155/2015/547250. Epub 2015 Aug 27.

Abstract

Preoperative 3D CT imaging techniques provide displacement analysis of the distal scaphoid fragment in 3D space, using the matched opposite scaphoid as reference. Its accuracy depends on the presence of anatomical bilateral symmetry, which has not been investigated yet using similar techniques. Our purpose was to investigate symmetry by comparing the relative positions of distal and proximal poles between sides. We used bilateral CT scans of 19 adult healthy volunteers to obtain 3D scaphoid models. Left proximal and distal poles were matched to corresponding mirrored right sides. The left-to-right positional differences between poles were quantified in terms of three translational and three rotational parameters. The mean (SD) of ulnar, dorsal, and distal translational differences of distal poles relative to proximal poles was 0.1 (0.6); 0.4 (1.2); 0.2 (0.6) mm and that of palmar rotation, ulnar deviation, and pronation differences was -1.1 (4.9); -1.5 (3.3); 1.0 (3.7)°, respectively. These differences did not significantly differ from zero and thus were not biased to left or right side. We proved that, on average, the articular surfaces of scaphoid poles were symmetrically aligned in 3D space. This suggests that the contralateral scaphoid can serve as reference in corrective surgery. No level of evidence is available.

摘要

术前三维CT成像技术以配对的对侧舟骨为参照,在三维空间中对舟骨远侧骨折块进行移位分析。其准确性取决于解剖学双侧对称性的存在,而目前尚未使用类似技术对此进行研究。我们的目的是通过比较两侧舟骨远侧和近侧极的相对位置来研究对称性。我们使用了19名成年健康志愿者的双侧CT扫描来获取三维舟骨模型。将左侧的近侧和远侧极与相应的镜像右侧进行匹配。极之间的左右位置差异通过三个平移参数和三个旋转参数进行量化。远侧极相对于近侧极的尺侧、背侧和远侧平移差异的平均值(标准差)分别为0.1(0.6)mm、0.4(1.2)mm、0.2(0.6)mm,掌侧旋转、尺侧偏斜和旋前差异的平均值(标准差)分别为-1.1(4.9)°、-1.5(3.3)°、1.0(3.7)°。这些差异与零无显著差异,因此不存在偏向左侧或右侧的情况。我们证明,平均而言,舟骨极的关节面在三维空间中呈对称排列。这表明在矫正手术中对侧舟骨可作为参照。本研究无证据分级。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3a85/4564638/8139bc96d9bb/BMRI2015-547250.001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验