Mangum L Colby, Sutherlin Mark A, Saliba Susan A, Hart Joseph M
University of Virginia Exercise and Sport Injury Laboratory, 210 Emmet St South, Charlottesville, VA 22904(∗).
University of Virginia Exercise and Sport Injury Laboratory, 210 Emmet St South, Charlottesville, VA 22904(†).
PM R. 2016 Apr;8(4):340-347. doi: 10.1016/j.pmrj.2015.09.015. Epub 2015 Sep 30.
To determine the reliability of measurement of muscle activation via ultrasound imaging measures of the transverse abdominis (TrA) and lumbar multifidus (LM) in tabletop, seated, standing, and walking conditions.
Descriptive laboratory study.
University research laboratory.
Sixteen healthy participants (age, 20.4 ± 1.8 years; height, 167.7 ± 9.0 cm; mass, 65.1 ± 10.8 kg).
None.
The activation ratio (AR) of TrA and LM and preferential activation ratio of TrA in tabletop, seated, standing, and walking positions were assessed by the same examiner during 2 ultrasound imaging sessions 24-72 hours apart. Statistical analysis included determination of intraclass correlation coefficients (ICCs) using analysis of variance for each muscle and position between sessions.
Excellent reliability was found in TrA AR between sessions for healthy participants in the tabletop position (ICC3,k = 0.903), and acceptable to excellent reliability was found in seated (ICC3,k = 0.613), standing (ICC3,k = 0.553), and walking (ICC3,k = 0.737) positions. LM AR was fair in the tabletop position for these participants (ICC3,k = 0.264). The preferential activation ratio for healthy participants was substantially reliable in tabletop and seated positions (ICC3,k = 0.668, 0.684) and showed fair reliability for walking (ICC3,k = 0.455).
Ultrasound imaging is a reliable method of measuring muscle thickness across multiple positions in healthy persons. This measure may be used to compare abdominal muscle thickness across populations or after interventions. LM AR was only found to be reliable in the tabletop position.
确定在桌面、坐姿、站立和行走状态下,通过超声成像测量腹横肌(TrA)和腰多裂肌(LM)肌肉激活的可靠性。
描述性实验室研究。
大学研究实验室。
16名健康参与者(年龄20.4±1.8岁;身高167.7±9.0厘米;体重65.1±10.8千克)。
无。
同一名检查者在间隔24 - 72小时的两次超声成像检查期间,评估TrA和LM的激活率(AR)以及在桌面、坐姿、站立和行走姿势下TrA的优先激活率。统计分析包括使用方差分析确定各肌肉和各姿势在两次检查之间的组内相关系数(ICC)。
对于健康参与者,在桌面姿势下,TrA的AR在两次检查之间具有极好的可靠性(ICC3,k = 0.903),在坐姿(ICC3,k = 0.613)、站立(ICC3,k = 0.553)和行走(ICC3,k = 0.737)姿势下具有可接受至极好的可靠性。对于这些参与者,LM的AR在桌面姿势下为中等(ICC3,k = 0.264)。健康参与者的优先激活率在桌面和坐姿下具有较高的可靠性(ICC3,k = 0.668, 0.684),在行走时可靠性中等(ICC3,k = 0.455)。
超声成像是测量健康人多个姿势下肌肉厚度的可靠方法。该测量方法可用于比较不同人群或干预后的腹肌厚度。仅在桌面姿势下发现LM的AR具有可靠性。