Suppr超能文献

对侧抑制下瞬态诱发耳声发射测量的可靠性

Reliability of measures of transient evoked otoacoustic emissions with contralateral suppression.

作者信息

Stuart Andrew, Cobb Kensi M

机构信息

East Carolina University, United States.

East Carolina University, United States.

出版信息

J Commun Disord. 2015 Nov-Dec;58:35-42. doi: 10.1016/j.jcomdis.2015.09.003. Epub 2015 Sep 12.

Abstract

The reliability of measures of transient evoked otoacoustic emissions (TEOAEs) with contralateral suppression was examined. The effect of test session (i.e., initial test; retest without probe removal; retest with probe removal; and retest 1-2 days post initial test), gender, and ear was examined in 14 young adult females and 14 young adult males. TEOAEs were obtained bilaterally with 60 dB peSPL linear click stimuli with and without a contralateral 65 dB SPL broadband noise suppressor. Absolute TEOAE suppression and a normalized index of TEOAE suppression (i.e., percentage of suppression) were examined. Reliability of these measures was assessed with repeated measures linear mixed model analysis of variance, a coefficient of reliability, and Bland-Altman analyses. There were no statistically significant (p>0.05) main effects of test, gender, and ear or interactions for both absolute dB and % TEOAE suppression values. Cronbach's α were greater than 0.90 across the four tests for both TEOAE measures. Mean test differences or bias (i.e., between the initial and subsequent tests) for absolute and % TEOAE suppression ranged from -0.05 to 0.11 dB and -1.5% to 1.1%, respectively. There was no proportional/systematic bias with the mean differences of the first and subsequent measurements. Data herein were consistent with the view that bilateral TEOAE suppression measures are reliable across test sessions of 1-2 days among females and males and may provide a method to monitor medial olivocochlear efferent reflex status over time.

摘要

对具有对侧抑制的瞬态诱发耳声发射(TEOAEs)测量的可靠性进行了检查。在14名年轻成年女性和14名年轻成年男性中,研究了测试阶段(即初次测试;不拔探头的复测;拔探头的复测;初次测试后1 - 2天的复测)、性别和耳朵对TEOAEs的影响。使用60 dB peSPL线性短声刺激双侧获取TEOAEs,同时施加和不施加65 dB SPL对侧宽带噪声抑制器。检查了绝对TEOAEs抑制和TEOAEs抑制的归一化指数(即抑制百分比)。通过重复测量线性混合模型方差分析、可靠性系数和Bland - Altman分析评估了这些测量的可靠性。对于绝对分贝和TEOAEs抑制百分比值,测试、性别和耳朵的主效应或交互作用均无统计学显著性(p>0.05)。两种TEOAEs测量在四次测试中的Cronbach's α均大于0.90。绝对和TEOAEs抑制百分比的平均测试差异或偏差(即初次测试与后续测试之间)分别为 - 0.05至0.11 dB和 - 1.5%至1.1%。首次测量与后续测量的平均差异不存在比例/系统偏差。本文数据与以下观点一致,即双侧TEOAEs抑制测量在1 - 2天的测试阶段中,在女性和男性中都是可靠的,并且可能提供一种随时间监测内侧橄榄耳蜗传出反射状态的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验