Suppr超能文献

一种用于直接检测温带和亚热带水域中大肠杆菌的廉价生长培养基的评估

Evaluation of an Inexpensive Growth Medium for Direct Detection of Escherichia coli in Temperate and Sub-Tropical Waters.

作者信息

Bain Robert E S, Woodall Claire, Elliott John, Arnold Benjamin F, Tung Rosalind, Morley Robert, du Preez Martella, Bartram Jamie K, Davis Anthony P, Gundry Stephen W, Pedley Stephen

机构信息

UNICEF, New York, United States of America.

School of Chemistry, University of Bristol, Bristol, United Kingdom.

出版信息

PLoS One. 2015 Oct 23;10(10):e0140997. doi: 10.1371/journal.pone.0140997. eCollection 2015.

Abstract

The cost and complexity of traditional methods for the detection of faecal indicator bacteria, including E. coli, hinder widespread monitoring of drinking water quality, especially in low-income countries and outside controlled laboratory settings. In these settings the problem is exacerbated by the lack of inexpensive media for the detection of E. coli in drinking water. We developed a new low-cost growth medium, aquatest (AT), and validated its use for the direct detection of E. coli in temperate and sub-tropical drinking waters using IDEXX Quanti-Tray®. AT was compared with IDEXX Colilert-18® and either EC-MUG or MLSB for detecting low levels of E. coli from water samples from temperate (n = 140; Bristol, UK) and subtropical regions (n = 50, Pretoria/Tshwane, South Africa). Confirmatory testing (n = 418 and 588, respectively) and the comparison of quantitative results were used to assess performance. Sensitivity of AT was higher than Colilert-18® for water samples in the UK [98.0% vs. 86.9%; p<0.0001] and South Africa [99.5% vs. 93.2%; p = 0.0030]. There was no significant difference in specificity, which was high for both media (>95% in both settings). Quantitative results were comparable and within expected limits. AT is reliable and accurate for the detection of E. coli in temperate and subtropical drinking water. The composition of the new medium is reported herein and can be used freely.

摘要

检测包括大肠杆菌在内的粪便指示菌的传统方法成本高昂且操作复杂,这阻碍了对饮用水质量的广泛监测,尤其是在低收入国家以及在受控实验室环境之外的地区。在这些环境中,由于缺乏用于检测饮用水中大肠杆菌的廉价培养基,问题变得更加严重。我们开发了一种新型低成本生长培养基——水测试培养基(aquatest,简称AT),并使用IDEXX Quanti-Tray®验证了其在温带和亚热带饮用水中直接检测大肠杆菌的用途。将AT与IDEXX Colilert-18®以及EC-MUG或MLSB进行比较,以检测来自温带地区(n = 140;英国布里斯托尔)和亚热带地区(n = 50,南非比勒陀利亚/茨瓦内)水样中的低水平大肠杆菌。通过确证测试(分别为n = 418和588)以及定量结果比较来评估性能。在英国水样中,AT的灵敏度高于Colilert-18® [98.0%对86.9%;p<0.0001],在南非水样中也是如此[99.5%对93.2%;p = 0.0030]。两种培养基的特异性无显著差异,且在两种环境下特异性都很高(均>95%)。定量结果具有可比性且在预期范围内。AT对于温带和亚热带饮用水中大肠杆菌的检测是可靠且准确的。本文报告了这种新培养基的成分,可免费使用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e60c/4619692/fa3868faaf63/pone.0140997.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验