Suppr超能文献

印度受试者中近距离工作诱发的短暂性近视

Near work-induced transient myopia in Indian subjects.

作者信息

Sivaraman Viswanathan, Rizwana Jameel H, Ramani Krishnakumar, Price Holly, Calver Richard, Pardhan Shahina, Vasudevan Balamurali, Allen Peter M

机构信息

Elite School of Optometry, Chennai, India.

Department of Vision and Hearing Sciences, Anglia Ruskin University, Cambridge, UK.

出版信息

Clin Exp Optom. 2015 Nov;98(6):541-6. doi: 10.1111/cxo.12306. Epub 2015 Oct 25.

Abstract

PURPOSE

The aim was to determine the characteristics of near work-induced transient myopia (NITM) in asymptomatic Indian subjects and the influence of target size and contrast.

METHODS

Two studies were conducted: First, 24 myopes and 24 emmetropes viewed four targets (N8 and N12 with 50 and 90 per cent contrasts) placed at 0.2 m for five minutes. The refractive status was assessed objectively, before and after carrying out the near task, with the Grand Seiko WAM-5500 open-field autorefractor under monocular viewing conditions. Second, a different group of 24 myopes and 24 emmetropes viewed a N12 target with 90 per cent contrast for 60 minutes with pre- and post-refractive state measurements repeated as above. NITM was defined as the difference between pre-task and post-task distance refraction.

RESULTS

In the first study, myopes demonstrated an initial post-task myopic shift of 0.21 D, whereas emmetropes demonstrated a small hyperopic shift of 0.07 D (p < 0.001). The myopes demonstrated a decay time constant of 6.07 seconds. There was no effect of target size or contrast on the magnitude of the NITM or the decay time constant (p > 0.05). In the second study, myopes showed a NITM of 0.31 D, which was significantly greater than emmetropes (p < 0.001). The myopes demonstrated a decay time constant of 8.16 seconds.

CONCLUSION

The magnitude of the NITM was higher in myopes compared to emmetropes for both five minute and 60 minute viewing time. The NITM decayed slightly faster than that found in previous literature for some other ethnic groups. Potential reasons for these findings are discussed.

摘要

目的

本研究旨在确定无症状印度受试者中近工作诱发的短暂性近视(NITM)的特征以及目标大小和对比度的影响。

方法

进行了两项研究:首先,24名近视者和24名正视者观看放置在0.2米处的四个目标(对比度为50%和90%的N8和N12),持续五分钟。在单眼观察条件下,使用Grand Seiko WAM - 5500开放式自动验光仪在进行近工作任务前后客观评估屈光状态。其次,另一组24名近视者和24名正视者观看对比度为90%的N12目标60分钟,屈光状态测量如前重复。NITM定义为任务前和任务后远距离屈光的差值。

结果

在第一项研究中,近视者在任务后出现了0.21 D的初始近视偏移,而正视者出现了0.07 D的小远视偏移(p < 0.001)。近视者的衰减时间常数为6.07秒。目标大小或对比度对NITM的幅度或衰减时间常数没有影响(p > 0.05)。在第二项研究中,近视者的NITM为0.31 D,显著大于正视者(p < 0.001)。近视者的衰减时间常数为8.16秒。

结论

在五分钟和六十分钟的观看时间内,近视者的NITM幅度均高于正视者。NITM的衰减速度比先前文献中其他一些种族群体的情况略快。讨论了这些发现的潜在原因。