Suppr超能文献

与传统注射器冲洗相比,使用GentleWave™系统冲洗时产生的根尖压力。

Apical pressure created during irrigation with the GentleWave™ system compared to conventional syringe irrigation.

作者信息

Haapasalo Markus, Shen Ya, Wang Zhejun, Park Ellen, Curtis Allison, Patel Payal, Vandrangi Prashanthi

机构信息

Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, 2199 Wesbrook Mall, Vancouver, BC, V6T 1Z3, Canada.

Sonendo, Inc., Laguna Hills, CA, USA.

出版信息

Clin Oral Investig. 2016 Sep;20(7):1525-34. doi: 10.1007/s00784-015-1632-z. Epub 2015 Oct 26.

Abstract

OBJECTIVES

The purpose of this study is to compare pressures at the apical foramen created by conventional syringe irrigation and the GentleWave™ System, which releases high-velocity degassed irrigants to the pulp chamber and uses broad-spectrum sound energy for cleaning.

MATERIALS AND METHODS

The apical pressure generated during irrigation was measured for palatal and distobuccal root canals of four extracted maxillary molars after no instrumentation, minimal instrumentation to a size #15/.04, instrumentation to a size #40/.04 taper, and after perforating the apical foramen to size #40. The root canals opened into an air-tight custom fixture coupled to a piezoresistive pressure transducer. Apical pressures were measured for the GentleWave™ System and syringe-needle irrigation at different irrigant flow rates, with the needle tip at 1 and 3 mm from the apical foramen using 30-gauge (G) open-ended or side-vented safety tip needles.

RESULTS

The GentleWave™ System generated negative apical pressures (P < 0.001 compared with syringe irrigation); the mean pressures were between -13.07 and -17.19 mmHg. The 30 G needles could not reach the 1 and 3 mm from the working length in uninstrumented and 1 mm in minimally instrumented canals. The mean positive pressures between 6.46 and 110.34 mmHg were measured with needle irrigation depending on the flow rate, needle insertion depth, and size of the root canal.

CONCLUSIONS

The GentleWave™ System creates negative pressure at the apical foramen during root canal cleaning irrespective of the size of canal instrumentation. Positive apical pressures were measured for syringe irrigation.

CLINICAL RELEVANCE

Negative pressure during irrigation contributes to improved safety as compared to high-positive pressure.

摘要

目的

本研究旨在比较传统注射器冲洗和GentleWave™系统在根尖孔处产生的压力,后者可向髓腔释放高速脱气冲洗液,并利用广谱声能进行清洁。

材料与方法

对四颗拔除的上颌磨牙的腭侧和远中颊侧根管,在未进行器械预备、预备至15号/.04规格、预备至40号/.04锥度以及根尖孔穿孔至40号后,测量冲洗过程中产生的根尖压力。根管开口接入与压阻式压力传感器相连的气密定制装置。使用30号(G)开口或侧孔安全尖端针,在不同冲洗液流速下,将针尖置于距根尖孔1和3毫米处,测量GentleWave™系统和注射器针头冲洗的根尖压力。

结果

GentleWave™系统产生负根尖压力(与注射器冲洗相比,P < 0.001);平均压力在-13.07至-17.19 mmHg之间。30G针在未预备根管中无法到达距工作长度1和3毫米处,在轻度预备根管中无法到达距工作长度1毫米处。根据流速、针插入深度和根管大小,注射器针头冲洗测得的平均正压力在6.46至110.34 mmHg之间。

结论

无论根管预备的大小如何,GentleWave™系统在根管清洁过程中都会在根尖孔处产生负压。注射器冲洗测得的是正根尖压力。

临床意义

与高正压相比,冲洗过程中的负压有助于提高安全性。