Kahraman Nail, Yumun Gunduz, Gücü Arif, Özsin Kadir K, Taner Temmuz, Şener Ebru, Göncü Mehmet T
Bursa Yuksek Ihtisas Education and Research Hospital, Bursa, Turkey.
Namik Kemal University, Tekirdag, Turkey.
Cardiovasc J Afr. 2016;27(3):159-163. doi: 10.5830/CVJA-2015-078. Epub 2015 Oct 28.
The saphenous vein is the most commonly used graft in coronary artery bypass surgery, since no suitable arterial graft is available. However, the frequency of late graft failure is a cause for research into graft protection. The objective of this study was to investigate the effect of synthetic adhesive cyanoacrylate administration on the saphenous vein graft for preventing vascular damage due to internal pressure on the graft.
In this study we enrolled 20 volunteer subjects who had undergone coronary artery bypass surgery and who had excess saphenous vein grafts. Perivascular cyanoacrylate was administered to one of two saphenous vein grafts explanted from each patient. The other saphenous vein graft from each patient was not treated and was used as the control. A model of the arterial system was created using a saphenous vein cardiopulmonary bypass system. Circulation was maintained at 120 mmHg for 45 minutes. Afterwards, the grafts were subjected to histopathological examination.
The cyanoacrylate group of grafts did not develop severe vascular damage compared with many instances of moderate and severe damage due to compression in the control group of grafts (p = 0.003).
Perivascular administration of cyanoacrylate appeared to be successful in the prevention of early saphenous vein graft injury. No in vivo study has been performed to date to assess endothelial damage in the saphenous vein, in order to demonstrate the long-term effect of cyanoacrylate. Further investigations are needed in this regard.
由于没有合适的动脉移植物,大隐静脉是冠状动脉搭桥手术中最常用的移植物。然而,晚期移植物失败的频率促使人们对移植物保护进行研究。本研究的目的是探讨给予合成粘合剂氰基丙烯酸酯对大隐静脉移植物的影响,以防止移植物内部压力导致的血管损伤。
在本研究中,我们招募了20名接受过冠状动脉搭桥手术且有多余大隐静脉移植物的志愿者。对从每位患者取出的两条大隐静脉移植物之一给予血管周围氰基丙烯酸酯。每位患者的另一条大隐静脉移植物不进行处理,用作对照。使用大隐静脉体外循环系统创建动脉系统模型。循环维持在120 mmHg 45分钟。之后,对移植物进行组织病理学检查。
与对照组移植物因受压出现许多中度和重度损伤的情况相比,氰基丙烯酸酯组的移植物未出现严重血管损伤(p = 0.003)。
血管周围给予氰基丙烯酸酯似乎成功预防了早期大隐静脉移植物损伤。迄今为止,尚未进行体内研究来评估大隐静脉内皮损伤,以证明氰基丙烯酸酯的长期效果。在这方面需要进一步研究。