Kroeff E P, Owens R A, Campbell E L, Johnson R D, Marks H I
Department of Biosynthetic Isolation and Purification Development, Lilly Research Laboratories, Indianapolis, IN 46285.
J Chromatogr. 1989 Jan 6;461:45-61. doi: 10.1016/s0021-9673(00)94274-2.
A process based on reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed for the purification of biosynthetic human insulin (BHI). The RP-HPLC procedure has been successfully integrated into the multimodal chromatographic production process used to purify kilogram quantities of BHI. Axial compression column technology was used in the scale-up process. The RP-HPLC procedure yields an insulin product having high chemical purity and full biological activity.
已开发出一种基于反相高效液相色谱(RP-HPLC)的方法来纯化生物合成人胰岛素(BHI)。RP-HPLC程序已成功整合到用于纯化数千克BHI的多模式色谱生产过程中。在放大过程中使用了轴向压缩柱技术。RP-HPLC程序产生的胰岛素产品具有高化学纯度和完全的生物活性。