未增强T1加权图像上齿状核和苍白球的高信号强度:基于大环钆的造影剂钆布醇的评估

High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol.

作者信息

Radbruch Alexander, Weberling Lukas D, Kieslich Pascal J, Hepp Johanna, Kickingereder Philipp, Wick Wolfgang, Schlemmer Heinz-Peter, Bendszus Martin

机构信息

From the *Department of Neuroradiology, University of Heidelberg Medical Center; †Department of Radiology, German Cancer Research Center, Heidelberg; ‡Department of Psychology, University of Mannheim, Mannheim; §Central Institute of Mental Health, University of Heidelberg; and ∥Neurology Clinic, University of Heidelberg Medical Center, Heidelberg, Germany.

出版信息

Invest Radiol. 2015 Dec;50(12):805-10. doi: 10.1097/RLI.0000000000000227.

Abstract

OBJECTIVE

The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-based contrast agent gadobutrol.

MATERIALS AND METHODS

Thirty patients who had received at least 5 MRI examinations (plus an additional last MRI for reference) with the exclusive use of gadobutrol, resulting in a total cumulative dose of 54.1 ± 30.4 mL gadobutrol, were analyzed retrospectively. Signal intensity ratio differences were calculated for DN-to-pons, DN-to-CSF, and GP-to-thalamus ratios by subtracting the SI ratio at the first MRI from the SI ratio at the last MRI scan. One-sample t tests were employed to examine if they differed from 0. Regression and correlational analyses were performed to examine whether the SI ratio differences were predicted by a number of control variables.

RESULTS

Signal intensity ratio differences did not differ significantly from 0, neither for the DN-to-pons ratio (-0.0035 ± 0.0476, P = 0.69), the DN-to-CSF ratio (-0.0539 ± 0.3217, P = 0.37), nor the GP-to-thalamus ratio (-0.0020 ± 0.0211, P = 0.60). None of the control variables predicted changes in SI ratios.

CONCLUSIONS

In contrast to a recently published study, we did not find signal increases in the DN or in the GP after serial injections of gadobutrol, even though the total dose applied here was considerably larger than in the respective study. This finding adds further support to the hypothesis that the molecular structure of a gadolinium-based contrast agent as either macrocyclic or linear is a crucial factor for its potential to cause gadolinium deposition in the brain. Future studies should further assess this hypothesis by additional animal investigations as well as histopathological and clinical correlation studies.

摘要

目的

本研究的目的是比较在连续注射大环钆基造影剂钆布醇后,未增强的T1加权磁共振成像(MRI)扫描中齿状核(DN)与脑桥、DN与脑脊液(CSF)以及苍白球(GP)与丘脑的信号强度(SI)比值的变化。

材料与方法

回顾性分析30例仅使用钆布醇进行了至少5次MRI检查(外加最后一次MRI作为参考)的患者,钆布醇的总累积剂量为54.1±30.4 mL。通过用最后一次MRI扫描时的SI比值减去第一次MRI时的SI比值,计算DN与脑桥、DN与CSF以及GP与丘脑比值的信号强度比值差异。采用单样本t检验来检验它们是否与0不同。进行回归和相关分析以检验SI比值差异是否由多个控制变量预测。

结果

DN与脑桥比值(-0.0035±0.0476,P = 0.69)、DN与CSF比值(-0.0539±0.3217,P = 0.37)以及GP与丘脑比值(-0.0020±0.0211,P = 0.60)的信号强度比值差异均未显著不同于0。没有一个控制变量能够预测SI比值的变化。

结论

与最近发表的一项研究不同,我们在连续注射钆布醇后未发现DN或GP的信号增加,尽管此处应用的总剂量比相应研究中的剂量大得多。这一发现进一步支持了以下假设,即钆基造影剂的分子结构(大环或线性)是其在脑内导致钆沉积潜力的关键因素。未来的研究应通过额外的动物研究以及组织病理学和临床相关性研究进一步评估这一假设。