Suppr超能文献

用于乳腺磁共振成像的先进扩散加权成像序列:改进序列与超高b值的综合比较以确定最佳组合

Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination.

作者信息

Hausmann Daniel, Todorski Inga, Pindur Alexandra, Weiland Elisabeth, Benkert Thomas, Bosshard Lars, Prummer Michael, Kubik-Huch Rahel A

机构信息

Department of Radiology, Kantonsspital Baden, 5404 Baden, Switzerland.

Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, Heidelberg University, 69117 Mannheim, Germany.

出版信息

Diagnostics (Basel). 2023 Feb 7;13(4):607. doi: 10.3390/diagnostics13040607.

Abstract

This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI and IR m-b1500 DWI were applied. z-DWI was acquired with the same measured b-values and e-b-values as the standard sequence. For IR m-b1500 DWI, b50 and b1500 were measured, and e-b2000 and e-b2500 were mathematically extrapolated. Three readers used Likert scales to independently analyze all ultra-high b-values (b1500-b2500) for each DWI with regards to scan preference and image quality. ADC values were measured in all 20 lesions. z-DWI was the most preferred (54%), followed by IR m-b1500 DWI (46%). b1500 was significantly preferred over b2000 for z-DWI and IR m-b1500 DWI ( = 0.001 and = 0.002, respectively). Lesion detection was not significantly different among sequences or b-values ( = 0.174). There were no significant differences in measured ADC values within lesions between s-DWI (ADC: 0.97 [±0.09] × 10 mm/s) and z-DWI (ADC: 0.99 [±0.11] × 10 mm/s; = 1.000). However, there was a trend toward lower values in IR m-b1500 DWI (ADC: 0.80 [±0.06] × 10 mm/s) than in s-DWI ( = 0.090) and z-DWI ( = 0.110). Overall, image quality was superior and there were fewer image artifacts when using the advanced sequences (z-DWI + IR m-b1500 DWI) compared with s-DWI. Considering scan preferences, we found that the optimal combination was z-DWI with a calculated b1500, especially regarding examination time.

摘要

本研究调查了两种扩散加权成像(DWI)乳腺磁共振成像(MRI)研究应用中的图像质量及超高b值的选择。研究队列包括40例患者(20个恶性病变)。除了具有两个中等b值(b50和b800)和三个高b值(e - b1500、e - b2000和e - b2500)的单次激发DWI(s - DWI)外,还应用了z - DWI和反转恢复中等b1500 DWI(IR m - b1500 DWI)。z - DWI采用与标准序列相同的测量b值和高b值进行采集。对于IR m - b1500 DWI,测量b50和b1500,并通过数学方法外推e - b2000和e - b2500。三位阅片者使用李克特量表,就扫描偏好和图像质量,对每个DWI的所有超高b值(b1500 - b2500)进行独立分析。在所有20个病变中测量了表观扩散系数(ADC)值。z - DWI是最受青睐的(54%),其次是IR m - b1500 DWI(46%)。对于z - DWI和IR m - b1500 DWI,b1500明显比b2000更受青睐(分别为P = 0.001和P = 0.002)。序列或b值之间的病变检测无显著差异(P = 0.174)。在病变内测量的ADC值,单次激发DWI(ADC:0.97 [±0.09]×10⁻³mm²/s)和z - DWI(ADC:0.99 [±0.11]×10⁻³mm²/s;P = 1.000)之间无显著差异。然而,IR m - b1500 DWI(ADC:0.80 [±0.06]×10⁻³mm²/s)的ADC值有低于单次激发DWI(P = 0.090)和z - DWI(P = 0.110)的趋势。总体而言,与单次激发DWI相比,使用先进序列(z - DWI + IR m - b1500 DWI)时图像质量更好,图像伪影更少。考虑扫描偏好,我们发现最佳组合是计算b值为1500的z - DWI,尤其是在检查时间方面。