Abstract

A method for measurements of mass concentration of black carbon particulate matter (PM) is proposed based on photothermal interferometry (PTI). A folded Jamin photothermal interferometer was used with a laser irradiation of particles deposited on a filter paper. The black carbon PM deposited on the filter paper was regarded as a film while the quartz filter paper was regarded as a substrate to establish a mathematical model for measuring the mass concentration of PM using a photothermal method. The photothermal interferometry system was calibrated and used to measure the atmospheric PM concentration corresponding to different dust-treated filter paper. The measurements were compared to those obtained using β ray method and were found consistent. This method can be particularly relevant to polluted atmospheres where PM is dominated by black carbon.

摘要

提出了一种基于光热干涉法(PTI)测量黑碳颗粒物(PM)质量浓度的方法。使用折叠式雅满干涉仪,对沉积在滤纸上的颗粒进行激光照射。将沉积在滤纸上的黑碳PM视为薄膜,而将石英滤纸视为基底,建立了用光热法测量PM质量浓度的数学模型。对光热干涉测量系统进行了校准,并用于测量与不同粉尘处理滤纸相对应的大气PM浓度。将测量结果与使用β射线法获得的结果进行比较,发现两者一致。该方法对于以黑碳为主的污染大气尤为适用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验