Albiero Alberto Maria, Benato Renato
Private Practice, Udine, Italy.
Int J Med Robot. 2016 Sep;12(3):453-60. doi: 10.1002/rcs.1715. Epub 2015 Nov 4.
Complications are frequently reported when combining computer assisted flapless surgery with an immediate loaded prefabricated prosthesis. The authors have combined computer-assisted surgery with the intraoral welding technique to obtain a precise passive fit of the immediate loading prosthesis.
An edentulous maxilla was rehabilitated with four computer assisted implants welded together intraorally and immediately loaded with a provisional restoration.
A perfect passive fit of the metal framework was obtained that enabled proper osseointegration of implants. Computer assisted preoperative planning has been shown to be effective in reducing the intraoperative time of the intraoral welding technique. No complications were observed at 1 year follow-up.
This guided-welded approach is useful to achieve a passive fit of the provisional prosthesis on the inserted implants the same day as the surgery, reducing intraoperative time with respect to the traditional intraoral welding technique. Copyright © 2015 John Wiley & Sons, Ltd.
在将计算机辅助无瓣手术与即刻加载的预制假体相结合时,并发症屡有报道。作者将计算机辅助手术与口内焊接技术相结合,以实现即刻加载假体的精确被动就位。
使用四颗通过计算机辅助植入且在口内焊接在一起的种植体修复无牙上颌骨,并即刻进行临时修复。
获得了金属框架的完美被动就位,使种植体能够实现良好的骨整合。计算机辅助术前规划已被证明可有效减少口内焊接技术的术中时间。在1年的随访中未观察到并发症。
这种引导焊接方法有助于在手术当天使临时假体在植入的种植体上实现被动就位,相对于传统的口内焊接技术减少了术中时间。版权所有© 2015约翰威立父子有限公司。