Suppr超能文献

Comparison Between Bench-Top and Computational Modelling of Cerebral Thromboembolism in Ventricular Assist Device Circulation.

作者信息

Clark William D, Eslahpazir Benjamin A, Argueta-Morales I Ricardo, Kassab Alain J, Divo Eduardo A, DeCampli William M

机构信息

Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd., Orlando, FL, 32816, USA.

College of Medicine, University of Central Florida, Orlando, FL, USA.

出版信息

Cardiovasc Eng Technol. 2015 Sep;6(3):242-55. doi: 10.1007/s13239-015-0230-1. Epub 2015 Jun 23.

Abstract

Despite improvements in ventricular assist devices (VAD) design, VAD-induced stroke rates remain remarkably high at 14-47%. We previously employed computational fluid dynamics (CFD) to propose adjustment of VAD outflow graft (VAD-OG) implantation to reduce stoke. Herein, we present an in-vitro model of cerebral vessel embolization in VAD-assisted circulation, and compare benchtop results to CFD predictions. The benchtop flow-loop consists of a 3D printed aortic bed using Accura 60 polymer driven by a continuous-flow pump. Three hundred spherical particles simulating thrombi of 2, 3.5, and 5 mm diameters were injected at the mock VAD-OG inlet. A water and glycerin mixture (3.8 cP viscosity) synthetically mimicked blood. The flowrate was adjusted to match the CFD Reynolds number. Catch cans were used to capture and count particles reaching cerebral vessels. VAD-OG geometries were evaluated using comparison of means Z-score range of -1.96 ≤ Z ≤ 1.96 to demonstrate overall agreement between computational and in-vitro techniques. Z-scores were: (i) Z = -1.05 for perpendicular (0°), (ii) Z = 0.32 for intermediate (30°), and (iii) Z = -0.52 for shallow (60°) anastomosis and confirmed agreement for all geometries. This study confirmed added benefits of using a left carotid artery bypass-graft with percent embolization reduction: 22.6% for perpendicular, 21.2% for intermediate, and 11.9% for shallow anastomoses. The shallow anastomosis demonstrated lower degrees of aortic arch flow recirculation, consistent with steady-flow computations. Quantitatively and qualitatively, contemporary steady-flow computational models for predicting VAD-induced cerebral embolization can be achieved in-vitro to validate the CFD equivalent.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验