Suppr超能文献

咀嚼运动的三维运动学和表面肌电图测量的可重复性

Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

作者信息

Remijn Lianne, Groen Brenda E, Speyer Renée, van Limbeek Jacques, Nijhuis-van der Sanden Maria W G

机构信息

HAN University of Applied Sciences, Institute of Health Studies, Postbox 6960, 6503 GL Nijmegen, The Netherlands; Sint Maartenskliniek Research, Postbox 9011, 6500 GM Nijmegen, The Netherlands.

Sint Maartenskliniek Research, Postbox 9011, 6500 GM Nijmegen, The Netherlands.

出版信息

Physiol Behav. 2016 Mar 1;155:112-21. doi: 10.1016/j.physbeh.2015.11.018. Epub 2015 Nov 23.

Abstract

The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables.

摘要

本研究的目的是确定评估咀嚼过程的程序的测量再现性,并估计三维运动学和表面肌电图(sEMG)变量的最小可检测差异。在两个阶段中,针对四种情况获取下颌运动的运动学和咀嚼肌的sEMG活动:两种尺寸(小和大)的两种食物质地(饼干和面包)。12名健康成年人(平均年龄29.1岁)完成了该研究。分析使用了5次咬合中第二次至第五次咀嚼周期的数据。使用组内相关系数(ICC)计算每个结果变量的再现性,并应用Bland-Altman分析来确定所有变量的测量标准误差、测量相对误差和最小可检测差异。所有结果变量的ICC范围为0.71至0.98。结果变量包括四个咬合变量和14个咀嚼周期变量。“吞咽时间”“运输时间”和“咀嚼周期数”的咬合变量测量相对标准误差高达17.3%,但“咀嚼侧改变”的测量相对标准误差范围为31.5%至57.0%。咀嚼周期变量的测量相对标准误差范围为4.1%至24.7%,运动学变量的测量相对标准误差小于sEMG变量。总体而言,使用三维运动学和sEMG获得的测量是评估咀嚼过程的可再现技术。咀嚼周期的持续时间和咀嚼频率是可重复性最好的测量指标。咀嚼侧的改变无法再现。已发表的测量误差和最小可检测差异将有助于解释未来使用相同研究变量的临床研究结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验