积分球手指光电容积脉搏波描记法:血液成分无创实际测量的初步研究

Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents.

作者信息

Yamakoshi Takehiro, Lee Jihyoung, Matsumura Kenta, Yamakoshi Yasuhiro, Rolfe Peter, Kiyohara Daiki, Yamakoshi Ken-ichi

机构信息

Department of Information and Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi Higashi-ku, Fukuoka-shi, Fukuoka, 811-0295, Japan.

Division of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Kita 14 Nishi 9, Kita-ku, Sapporo-shi, Hokkaido, 060-0814, Japan.

出版信息

PLoS One. 2015 Dec 4;10(12):e0143506. doi: 10.1371/journal.pone.0143506. eCollection 2015.

Abstract

The aim of this study was to compare conventional photoplethysmography (PPG) in a finger with PPG using an integrating sphere (ISPPG) to enhance scattered light collection. Two representative wavelengths were used; 1160 nm, a window through the absorption spectra of water and alcohol, and 1600 nm around where water absorption is high and there is an absorption peak of blood glucose. Simultaneous transmission-type measurements were made with conventional PPG and with ISPPG for each wavelength in the tips of index fingers of both hands in a total of 10 healthy young male and female volunteers (21.7 ± 1.6 years old). During a 5 min period in which subjects were in a relaxed state we determined the signal-to-noise ratio, SNR, and the PPG detectability (or sensitivity) by the two techniques. SNR during the test period was significantly higher with ISPPG as compared with conventional PPG, especially for the 1600 nm wavelength. PPG signals with 1600 nm could scarcely be detected by conventional PPG, while they could be detected with good sensitively by ISPPG. We conclude that under controlled conditions ISPPG has better SNR and higher sensitivity than conventional transmission PPG, especially in wavelength regions where water absorption is high but where there is potential for practical measurement of blood constituents including glucose.

摘要

本研究的目的是比较手指处的传统光电容积脉搏波描记法(PPG)与使用积分球的光电容积脉搏波描记法(ISPPG),以增强散射光的收集。使用了两个代表性波长;1160 nm,这是水和酒精吸收光谱中的一个窗口,以及1600 nm左右,此处水吸收较高且存在血糖吸收峰。对总共10名健康年轻男女志愿者(21.7±1.6岁)双手食指指尖的每个波长,同时进行传统PPG和ISPPG的透射型测量。在受试者处于放松状态的5分钟内,我们通过这两种技术确定了信噪比(SNR)和PPG可检测性(或灵敏度)。与传统PPG相比,测试期间ISPPG的SNR显著更高,尤其是对于1600 nm波长。传统PPG几乎无法检测到1600 nm的PPG信号,而ISPPG能够以良好的灵敏度检测到它们。我们得出结论,在受控条件下,ISPPG比传统透射式PPG具有更好的SNR和更高的灵敏度,特别是在水吸收较高但有可能实际测量包括葡萄糖在内的血液成分的波长区域。