Physiol Meas. 2013 Mar;34(3):359-75. doi: 10.1088/0967-3334/34/3/359. Epub 2013 Feb 26.
Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress.
从耳朵导出的归一化脉搏体积(NPV)有可能成为监测日常生活压力的实用指标。然而,耳朵 NPV 尚未得到验证。因此,我们比较了使用传输光体积描记法作为参考的食指 NPV、使用反射光体积描记法的中指和耳朵的四个部位的 NPV,在基线和进行冷热水浸泡时,在 10 名年轻和 6 名中年受试者中进行。结果表明,与基线值相比,冷水中的对数转换 NPV(lnNPV)明显较低,仅在食指、中指和耳道底部。此外,食指的 lnNPV 反应性(ΔlnNPV;基线值和测试值之间的差异)与中指和耳道底部的 ΔlnNPV 显著相关(年轻:r = 0.90 和 0.62,中年:r = 0.80 和 0.58)。总之,这些发现表明,反射和传输光体积描记法是与我们的理论预测一致的导出 NPV 的可比较方法。耳道底部的 NPV 是一种有效的方法,可用于评估日常生活压力。