Suppr超能文献

在单侧全膝关节置换术后,在顺应性表面行走不会增加运动步态不对称性。

Walking on a compliant surface does not enhance kinematic gait asymmetries after unilateral total knee arthroplasty.

作者信息

Bjerke Joakim, Öhberg Fredrik, Nilsson Kjell G, Stensdotter Ann-Katrin

机构信息

Department of Community Medicine and Rehabilitation Physiotherapy, Umeå University, 901 87, Umeå, Sweden.

Department of Physiotherapy, Faculty of Health and Social Sciences, Norwegian University of Science and Technology, NTNU, 7491, Trondheim, Norway.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2016 Aug;24(8):2606-13. doi: 10.1007/s00167-015-3931-y. Epub 2015 Dec 26.

Abstract

PURPOSE

To investigate gait asymmetries and the effect of walking on compliant surfaces in individuals with unilateral total knee arthroplasty (TKA), hypothesizing that asymmetries would increase as an effect of the compliant surface.

METHODS

Individuals with unilateral TKA ~19 months post-operative (n = 23, median age 59 years) recruited from one orthopaedic clinic and age- and gender-matched healthy individuals without knee complaints (n = 23, median age 56 years) walked at comfortable speed on a hard surface and on a compliant surface. 3D kinematic analyses were made for knee and hip angles in sagittal and frontal planes, stance time, step length, and gait velocity.

RESULTS

Shorter stance time (p < 0.01) and less peak knee flexion (p < 0.001) at weight bearing acceptance was found in the prosthetic side compared with the contralateral side. Larger knee (p < 0.01) and hip (p < 0.001) adduction was found compared with healthy controls. Neither asymmetries between the prosthetic and the contralateral side nor differences compared with healthy controls were enhanced when walking on compliant surfaces compared with hard surfaces.

CONCLUSION

The TKA group adapted their gait to compliant surfaces similarly to healthy controls. Gait asymmetries in the TKA group observed on hard surface were not enhanced, and adduction in hip and knee joints did not increase further as an effect of walking on compliant surfaces. Thus, unfavourable knee joint loading did not increase when walking on a compliant surface. This implies that recommendations for walking on soft surfaces to reduce knee joint loading are not counteracted by increased gait asymmetries and unfavourable joint loading configurations.

LEVEL OF EVIDENCE

III.

摘要

目的

研究单侧全膝关节置换术(TKA)患者的步态不对称性以及在顺应性表面行走的影响,假设顺应性表面会导致不对称性增加。

方法

从一家骨科诊所招募术后约19个月的单侧TKA患者(n = 23,中位年龄59岁),以及年龄和性别匹配、无膝关节问题的健康个体(n = 23,中位年龄56岁),让他们在硬表面和顺应性表面上以舒适的速度行走。对矢状面和额状面的膝关节和髋关节角度、站立时间、步长和步态速度进行三维运动学分析。

结果

与对侧相比,假体侧在负重接受时站立时间更短(p < 0.01),膝关节最大屈曲角度更小(p < 0.001)。与健康对照组相比,膝关节(p < 0.01)和髋关节(p < 0.001)内收角度更大。与在硬表面行走相比,在顺应性表面行走时,假体侧与对侧之间的不对称性以及与健康对照组相比的差异均未增加。

结论

TKA组在顺应性表面上行走时,其步态适应方式与健康对照组相似。在硬表面上观察到的TKA组步态不对称性并未增强,并且在顺应性表面行走时,髋关节和膝关节的内收角度也没有进一步增加。因此,在顺应性表面行走时,不利的膝关节负荷并未增加。这意味着,为减少膝关节负荷而建议在柔软表面行走的建议,不会因步态不对称性增加和不利的关节负荷配置而受到影响。

证据水平

III级。