用于心电图估计的分段搏动调制方法。

The segmented-beat modulation method for ECG estimation.

作者信息

Agostinelli A, Giuliani C, Fioretti S, Di Nardo F, Burattini L

出版信息

Annu Int Conf IEEE Eng Med Biol Soc. 2015 Aug;2015:2856-9. doi: 10.1109/EMBC.2015.7318987.

Abstract

Electrocardiographic (ECG) tracings corrupted by noise with frequency components in the ECG frequency band, may result useless unless appropriately processed. The estimation of the clean ECG from such recordings, however, is quite challenging; being linear filtering inappropriate. In the common situations in which the R peaks are detectable, template-based techniques have been proposed to estimate the ECG by a template-beat concatenation. However, such techniques have the major limit of not being able to reproduce physiological heart-rate and morphological variability. Thus, the aim of the present study was to propose the segmented-beat modulation method (SBMM) as the technique that overcomes such limit. The SBMM is an improved template-based technique that provides good-quality estimations of ECG tracings characterized by some heart-rate and morphological variability. It segments the template ECG beat into QRS and TUP segments and then, before concatenation, it applies a modulation/demodulation process to the TUP-segment so that the estimated-beat duration and morphology adjust to those of the corresponding original-beat. To test its performance, the SBMM was applied to 19 ECG tracings from normal subjects. There were no errors in estimating the R peak location, and the errors in the QRS and TUP segments were low (≤65 μV and ≤30 μV, respectively), with the former ones being significantly higher than the latter ones. Eventually, TUP errors tended to increase with increasing heart-rate variability (correlation coefficient: 0.59, P<;10(-2)). In conclusion, the new SBMM proved to be a useful tool for providing good-quality ECG estimations of tracings characterized by heart-rate and morphological variability.

摘要

被心电图频段中具有频率成分的噪声所破坏的心电图(ECG)描记图,若不进行适当处理可能会变得无用。然而,从这样的记录中估计出纯净的心电图极具挑战性,因为线性滤波并不适用。在R波峰可检测的常见情况下,已提出基于模板的技术,通过模板搏动拼接来估计心电图。然而,此类技术存在一个主要局限,即无法再现生理心率和形态变异性。因此,本研究的目的是提出分段搏动调制方法(SBMM)作为克服这一局限的技术。SBMM是一种改进的基于模板的技术,可对具有一定心率和形态变异性特征的心电图描记图进行高质量估计。它将模板心电图搏动分割为QRS段和TUP段,然后在拼接之前,对TUP段应用调制/解调过程,以使估计搏动的持续时间和形态与相应原始搏动的持续时间和形态相匹配。为测试其性能,将SBMM应用于19名正常受试者的心电图描记图。在估计R波峰位置时没有误差,QRS段和TUP段的误差较低(分别≤65 μV和≤30 μV),前者明显高于后者。最终,TUP误差倾向于随着心率变异性的增加而增加(相关系数:0.59,P<10⁻²)。总之,新的SBMM被证明是一种有用的工具,可对具有心率和形态变异性特征的描记图提供高质量的心电图估计。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验