Suppr超能文献

Different types of false positive anti-HIV reactions in patients on haemodialysis.

作者信息

Ujhelyi E, Füst G, Illei G, Gyodi E, Nagy K, Toth F D, Büki B, Dierich M P, Mayer V, Gal G

机构信息

National Institute of Haematology and Blood Transfusion, Budapest, Hungary.

出版信息

Immunol Lett. 1989 Jul;22(1):35-40. doi: 10.1016/0165-2478(89)90139-9.

Abstract

Serum samples of 589 haemodialysis patients were screened for HIV antibody by ELISA methods. Of these, 36 samples were found to be repeatedly reactive. None of the 36, however, could be confirmed by competitive enzyme immunoassays and Western blot; therefore, they were considered to be false positive. The sera could be divided in two groups. The sera of Group 1 were designated as the usual type of false positivity, caused most probably by anti-lymphocyte antibodies. In 19 sera, however, a special type of false positivity was found. These sera reacted strongly with the plates coated with the supernatants of HIV-infected cells but not with those of uninfected H9 cells. Three and two sera showed, respectively, positive immunofluorescence reaction with the HIV-infected, but not with the uninfected, H9 and CEM cells. Reactivity to HIV-infected H9 cells could be adsorbed from a part of these samples with lesser amounts of HIV-infected than uninfected H9 cells. This special type of false positivity was observed frequently (7/65) in patients who rejected a kidney graft. These findings suggest that this type of anti-HIV false positivity is due to antibodies reacting with cellular antigens present in HIV-infected but not in uninfected lymphocytes. Their appearance seems to be associated with the immunological activation occurring at graft rejection.

摘要

相似文献

1
Different types of false positive anti-HIV reactions in patients on haemodialysis.
Immunol Lett. 1989 Jul;22(1):35-40. doi: 10.1016/0165-2478(89)90139-9.
3
Immunofluorescence tests for HIV antibody and their value as confirmatory tests.
J Virol Methods. 1987 Aug;17(1-2):35-43. doi: 10.1016/0166-0934(87)90066-8.
4
Delineation of false-positive HIV antibody response in patients with renal failure and history of multiple transfusions.
Transfusion. 1989 Feb;29(2):119-23. doi: 10.1046/j.1537-2995.1989.29289146828.x.
9
Evaluation of HIV type 1 western blot-indeterminate blood donors for the presence of human or bovine retroviruses.
AIDS Res Hum Retroviruses. 1995 Mar;11(3):409-14. doi: 10.1089/aid.1995.11.409.

引用本文的文献

1
Laboratory tests for detection of human immunodeficiency virus type 1 infection.
Clin Diagn Lab Immunol. 1995 Nov;2(6):637-45. doi: 10.1128/cdli.2.6.637-645.1995.