To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.
Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 peripheral zones.
The mean intraclass correlations (ICCs) for intraobserver and interobserver reproducibility were almost perfect (0.81-0.99) for CT in all corneal zones and for ET in all but 2 peripheral zones. Intraobserver ICC was substantial (0.61-0.8) for superior peripheral area and interobserver ICC for superior and inferior peripheral positions. CT and ET decreased significantly from morning to afternoon sessions [-3.15 μm (P < 0.0001) and -0.52 μm (P < 0.0001), respectively]. ET correlated weakly to moderately with CT.
RTVue yields almost perfect reproducibility for CT and ET in central, paracentral, and peripheral lateral zones. Central CT and ET were significantly thinner in the afternoon compared with the morning.
基于对角膜厚度(CT)和上皮厚度(ET)的重复测量,评估傅里叶域眼前节光学相干断层扫描(RTVue)的可重复性,并测试这些参数的日间变化情况。
本前瞻性研究纳入了23名健康志愿者的23只眼睛。三名临床观察者使用RTVue在3个时间段内对CT和ET各进行3次连续测量,每个时间段进行9次测量。第1次测量在上午9点±1小时进行,第2次测量在同一天下午4点±1小时进行,第3次测量在2天后上午9点±1小时进行。在9个区域评估CT和ET:角膜顶点、4个旁中心区域和4个周边区域。
在所有角膜区域,观察者内和观察者间CT的平均组内相关系数(ICC)几乎为完美(0.81 - 0.99),除2个周边区域外,所有区域ET的平均组内相关系数也几乎为完美。上周边区域观察者内ICC为中等(0.61 - 0.8),上、下周边位置观察者间ICC为中等。CT和ET从上午到下午的测量值显著降低[-3.15μm(P < 0.0001)和-0.52μm(P < 0.0001)]。ET与CT呈弱至中度相关。
RTVue在中央、旁中心和周边外侧区域对CT和ET具有几乎完美的可重复性。与上午相比,下午中央CT和ET显著变薄。