Shin Jin-Ho, Park Jung-Min, Kim Ha-Jung, Ahn Jang-Hyuk, Kwak Byung-Man, Kim Jin-Man
Department of Food Science and Biotechnology of Animal Resources, Konkuk University, Seoul 143-701, Korea.
KOTITI Testing & Research Institute, Seongnam 462-807, Korea.
Korean J Food Sci Anim Resour. 2015;35(4):466-72. doi: 10.5851/kosfa.2015.35.4.466. Epub 2015 Aug 31.
A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.
开发了一种使用液相色谱串联质谱法(LC-MS/MS)的快速简便分析方法,用于检测婴儿配方奶粉中的肌醇(MI)。对于蛋白质去除:采用酸水解和通过有机溶剂萃取去除脂质。仪器分析的操作条件是基于先前报道的使用LC-MS/MS的类似方法确定的。采用定量分析进行检测限测试、婴儿配方奶粉回收率测试和标准参考物质(SRM)1849a测试,以验证我们开发的用于定量MI的LC-MS/MS分析方法的有效性。为了进行验证,将我们方法的结果与认证值的定量分析结果进行了比较。测试结果表明,检测限为0.05 mg/L,定量限为0.17 mg/L,方法检测限为17 mg/kg。回收率测试的回收率在98.07 - 98.43%之间,相对标准偏差在1.93 - 2.74%之间。因此,结果值良好。此外,测得SRM 1849a的MI含量为401.84 mg/kg,回收率为98.25%,与409 mg/kg的中位认证值相当。从上述结果来看,我们判断本研究中使用的仪器分析条件和制备方法是有效的。本文开发的快速分析方法可在许多寻求节省时间和人力的实验室中实施。