Suppr超能文献

两种高海拔心率变异性评估方法的比较。

A comparison of two methods of heart rate variability assessment at high altitude.

作者信息

Boos Christopher John, Bakker-Dyos Josh, Watchorn Jim, Woods David Richard, O'Hara John Paul, Macconnachie Lee, Mellor Adrian

机构信息

Department of Cardiology, Poole Hospital NHS Foundation trust, UK.

Department of Postgraduate Medical Education, Bournemouth University, Bournemouth, UK.

出版信息

Clin Physiol Funct Imaging. 2017 Nov;37(6):582-587. doi: 10.1111/cpf.12334. Epub 2016 Jan 14.

Abstract

Heart rate variability (HRV) is a useful index of autonomic function and has been linked to the development of high altitude (HA) related illness. However, its assessment at HA has been undermined by the relative expense and limited portability of traditional HRV devices which have mandated at least a minute heart rate recording. In this study, the portable ithlete HRV system, which uses a 55 s recording, was compared with a reference method of HRV which utilizes a 5 min electrocardiograph recording (CheckMyHeart ). The root mean squares of successive R-R intervals (RMSSD) for each device was converted to a validated HRV score (lnRMSSD × 20) for comparison. Twelve healthy volunteers were assessed for HRV using the two devices across seven time points at HA over 10 days. There was no significant change in the HRV values with either the ithlete (P = 0·3) or the CheckMyHeart (P = 0·19) device over the seven altitudes. There was also a strong overall correlation between the ithlete and CheckMyHeart device (r = 0·86; 95% confidence interval: 0·79-0·91). The HRV was consistently, though non-significantly higher with ithlete than with the CheckMyHeart device [mean difference (bias) 1·8 l; 95% CI -12·3 to 8·5]. In summary, the ithlete and CheckMyHeart system provide relatively similar results with good overall agreement at HA.

摘要

心率变异性(HRV)是自主神经功能的一项有用指标,且与高原(HA)相关疾病的发生有关。然而,在高原地区对其进行评估受到了传统HRV设备相对高昂的费用和有限的便携性影响,这些设备要求至少记录一分钟的心率。在本研究中,将使用55秒记录的便携式ithlete HRV系统与采用5分钟心电图记录(CheckMyHeart)的HRV参考方法进行了比较。将每个设备的连续R-R间期的均方根(RMSSD)转换为经过验证的HRV分数(lnRMSSD×20)进行比较。12名健康志愿者在10天内于高原地区的七个时间点使用这两种设备进行HRV评估。在七个海拔高度上,使用ithlete设备(P = 0·3)或CheckMyHeart设备(P = 0·19)时,HRV值均无显著变化。ithlete设备与CheckMyHeart设备之间也存在很强的总体相关性(r = 0·86;95%置信区间:0·79 - 0·91)。尽管差异不显著,但ithlete设备测得的HRV始终高于CheckMyHeart设备[平均差异(偏差)1·8 l;95% CI -12·3至8·5]。总之,ithlete设备和CheckMyHeart系统在高原地区提供了相对相似的结果,总体一致性良好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验