Plaza-Puche Ana B, El Aswad Amr, Arba-Mosquera Samuel, Wróbel-Dudzinska Dominika, Abdou Ahmed A, Alió Jorge L
J Refract Surg. 2016 Jan;32(1):6-13. doi: 10.3928/1081597X-20151207-06.
To evaluate corneal higher order aberrations after LASIK for the correction of high hyperopia using a 500-Hz excimer laser and optimized ablation profile.
Retrospective consecutive study including 51 eyes of 28 patients (age range: 21 to 54 years) with high hyperopia or hyperopic astigmatism (sphere ≥ 5.00 diopters). All cases underwent LASIK using the sixth generation Amaris excimer laser (SCHWIND eye-tech-solutions, Kleinostheim, Germany) and a femtosecond laser platform for flap creation. Postoperative changes in corneal higher order aberrations for the 4-, 5-, and 6-mm pupil diameters and corneal asphericity for 4.5 and 8 mm were represented at the end of the 6-month follow-up.
A significant increase in corneal root mean square higher order, spherical, and coma aberrations was observed 6 months after surgery (P < .01). Corneal asphericity for the 4.5-mm (Q45) and 8-mm (Q8) corneal diameter also changed significantly during the postoperative period (P < .01). Strehl ratio change was not statistically significant (P = .77).
Correction of high hyperopia with LASIK significantly induces corneal higher order aberrations regardless of the physiologic level of photopic and mesopic pupil conditions.
使用500赫兹准分子激光和优化的消融模式,评估准分子激光原位角膜磨镶术(LASIK)矫正高度远视后的角膜高阶像差。
回顾性连续研究,纳入28例(年龄范围:21至54岁)患有高度远视或远视散光(球镜度≥5.00屈光度)的患者的51只眼。所有病例均使用第六代阿玛里斯准分子激光(德国克莱诺施泰姆的SCHWIND眼科技解决方案公司)和飞秒激光平台制作角膜瓣进行LASIK手术。在6个月随访结束时,展示了4毫米、5毫米和6毫米瞳孔直径下角膜高阶像差的术后变化以及4.5毫米和8毫米角膜直径下的角膜非球面性变化。
术后6个月观察到角膜高阶像差、球差和慧差的均方根值显著增加(P <.01)。术后期间,4.5毫米(Q45)和8毫米(Q8)角膜直径的角膜非球面性也发生了显著变化(P <.01)。斯特列尔比变化无统计学意义(P = 0.77)。
无论明视和间视瞳孔条件的生理水平如何,LASIK矫正高度远视均会显著诱导角膜高阶像差。