Suppr超能文献

评估蜗周型人工耳蜗电极的NRT比值、耳蜗解剖结构与插入深度之间的关系。

Evaluation of the Relationship between the NRT-Ratio, Cochlear Anatomy, and Insertions Depth of Perimodiolar Cochlear Implant Electrodes.

作者信息

Mittmann Philipp, Rademacher Grit, Mutze Sven, Hassepass Frederike, Ernst Arneborg, Todt Ingo

机构信息

Department of Otolaryngology, ukb, 12683 Berlin, Germany.

Department of Radiology and Neuroradiology, ukb, 12683 Berlin, Germany.

出版信息

Biomed Res Int. 2015;2015:706253. doi: 10.1155/2015/706253. Epub 2015 Dec 29.

Abstract

The position of the cochlear implant electrode array within the scala tympani is essential for an optimal postoperative hearing benefit. If the electrode array changes in between the scalae intracochlearly (i.e., from scala tympani to scala vestibuli), a reduced auditory performance can be assumed. We established a neural response telemetry-ratio (NRT-ratio) which corresponds with the scalar position of the electrodes but shows within its limits a variability. The aim of this study was to determine if insertion depth angle or cochlea size influences the NRT-ratio. The intraoperative electrophysiological NRT data of 26 patients were evaluated. Using a flat panel tomography system, the position of the electrode array was evaluated radiologically. The insertion depth angle of the electrode, the cochlea size, and the NRT-ratio were calculated postoperatively. The radiological results were compared with the intraoperatively obtained electrophysiological data (NRT-ratio) and statistically evaluated. In all patients the NRT-ratio, the insertion depth angle, and the cochlea size could be determined. A significant correlation between insertional depth, cochlear size, and the NRT-ratio was not found. The NRT-ratio is a reliable electrophysiological tool to determine the scalar position of a perimodiolar electrode array. The NRT-ratio can be applied independent from insertion depth and cochlear size.

摘要

人工耳蜗电极阵列在鼓阶内的位置对于术后获得最佳听力益处至关重要。如果电极阵列在耳蜗内的不同阶之间发生移位(即从鼓阶移至前庭阶),则可推测听觉性能会降低。我们建立了一种神经反应遥测比率(NRT比率),它与电极的阶位置相对应,但在其范围内存在一定变异性。本研究的目的是确定插入深度角度或耳蜗大小是否会影响NRT比率。对26例患者的术中电生理NRT数据进行了评估。使用平板断层扫描系统,对电极阵列的位置进行了放射学评估。术后计算电极的插入深度角度、耳蜗大小和NRT比率。将放射学结果与术中获得的电生理数据(NRT比率)进行比较并进行统计学评估。在所有患者中,均可确定NRT比率、插入深度角度和耳蜗大小。未发现插入深度、耳蜗大小与NRT比率之间存在显著相关性。NRT比率是确定蜗轴周围电极阵列阶位置的可靠电生理工具。NRT比率的应用可独立于插入深度和耳蜗大小。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b4d9/4709608/d4af5cdf49b6/BMRI2015-706253.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验