Suppr超能文献

动物模型中深层基质角膜加法手术的临床、屈光和组织学可逆性

Clinical, Refractive and Histological Reversibility of Corneal Additive Surgery in Deep Stroma in an Animal Model.

作者信息

Ibares-Frías Lucía, Gallego Patricia, Cantalapiedra-Rodriguez Roberto, Merayo-Lloves Jesús, Martínez-García María Carmen

机构信息

a Optical Diagnostic Techniques Group, Theoretical, Atomic and Optical Physics Department , University of Valladolid , Valladolid , Spain.

b Ophthalmology Department , Hospital Clínico Universitario de Valladolid , Valladolid , Spain.

出版信息

Curr Eye Res. 2016 Sep;41(9):1192-201. doi: 10.3109/02713683.2015.1114652. Epub 2016 Feb 18.

Abstract

PURPOSE

The aim was to evaluate the reversibility of the clinical and histological changes induced in the corneas of an animal model after removing an intracorneal ring segment (ICRS).

METHODS

Surgery for this study was performed in 38 eyes of an experimental animal model (Gallus domesticus) for ICRS surgery (Ferrara technique). The animals without complications were randomized to two groups; in all of them, 1 segment was implanted in each eye and later removed at different times (1 and 3 months after implantation). In each group, after explantation, corneas were processed at different times for histological analysis with hematoxylin and eosin (H&E) stain and electronic microscopy. The refractive state of the eyes was also measured.

RESULTS

In corneas without complications (88.23%), explantation was performed correctly. During the first few days, around the area where the ICRS was implanted we observed deposits of cells and a moderate degree of corneal opacity (haze). These signs decreased progressively without disappearing completely. Histologically, at 7 days, we observed hyperplasia and abnormal arrangement of collagen fibers. Later, these findings also decreased in both groups, albeit at a faster rate in group 1. Minimal changes were observed in electron microscopy up to the end of the study in both groups. Preoperative refractive state was achieved at 1 month after explantation in both groups.

CONCLUSIONS

ICRS can safely be explanted from the cornea. Refractive reversibility was achieved at 1 month after explantation. However, the clinical and histological findings after ICRS explantation depend on the time from implantation to explantation.

摘要

目的

本研究旨在评估摘除角膜内环片(ICRS)后动物模型角膜中诱导的临床和组织学变化的可逆性。

方法

本研究的手术在用于ICRS手术(费拉拉技术)的实验动物模型(家鸡)的38只眼中进行。无并发症的动物被随机分为两组;在所有动物中,每只眼植入1个环片,随后在不同时间(植入后1个月和3个月)摘除。在每组中,摘除后,在不同时间对角膜进行苏木精和伊红(H&E)染色及电子显微镜检查的组织学分析。还测量了眼睛的屈光状态。

结果

在无并发症的角膜(88.23%)中,正确进行了摘除。在最初几天,在植入ICRS的区域周围,我们观察到细胞沉积和中度角膜混浊( haze)。这些体征逐渐减轻,但未完全消失。组织学上,在7天时,我们观察到胶原纤维增生和排列异常。后来,两组中的这些发现也有所减少,尽管第1组的减少速度更快。在两组研究结束前,电子显微镜下观察到的变化最小。两组在摘除后1个月均恢复到术前屈光状态。

结论

ICRS可以安全地从角膜中摘除。摘除后1个月实现了屈光可逆性。然而,ICRS摘除后的临床和组织学表现取决于从植入到摘除的时间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验