Wu Jian, Yin Xiaojin, Wang Wenyuan, Hong Xueming, Du Yu, Geng Youfu, Li Xuejin
Appl Opt. 2016 Feb 10;55(5):974-8. doi: 10.1364/AO.55.000974.
An all-fiber reflecting fluorescent temperature probe is proposed based on the simplified hollow-core photonic crystal fiber (SHC-PCF) filled with an aqueous CdSe/ZnS quantum dot solution. SHC-PCF is an excellent PCF used to fill liquid materials, which has low loss transmission bands in the visible wavelength range and enlarged core sizes. Both end faces of the SHC-PCF were spliced with multimode fiber after filling in order to generate a more stable and robust waveguide structure. The obtained temperature sensitivity dependence of the emission wavelength and the self-referenced intensity are 126.23 pm/°C and -0.007/°C in the temperature range of -10°C-120°C, respectively.
提出了一种全光纤反射荧光温度探头,该探头基于填充有CdSe/ZnS量子点水溶液的简化空心光子晶体光纤(SHC-PCF)。SHC-PCF是一种用于填充液体材料的优质光子晶体光纤,在可见光波长范围内具有低损耗传输带且纤芯尺寸增大。填充后,将SHC-PCF的两个端面与多模光纤进行熔接,以产生更稳定、更坚固的波导结构。在-10°C至120°C的温度范围内,发射波长和自参考强度的温度灵敏度依赖性分别为126.23 pm/°C和-0.007/°C。