Suppr超能文献

通过计算机辅助自动免疫荧光分析检测抗双链DNA抗体。

Detection of anti-dsDNA antibodies by computer-aided automated immunofluorescence analysis.

作者信息

Lakos Gabriella, Gonzalez Marlene, Flaherty David, Bentow Chelsea, Ibarra Claudia, Stimson Deborah, Nacario Lori, Hiemann Rico, Dervieux Thierry

机构信息

Inova Diagnostics, Inc, San Diego, CA, USA.

Inova Diagnostics, Inc, San Diego, CA, USA.

出版信息

J Immunol Methods. 2016 Jun;433:17-22. doi: 10.1016/j.jim.2016.02.019. Epub 2016 Feb 24.

Abstract

INTRODUCTION

NOVA View is a computer aided fluorescence microscope that is used for the automated reading and interpretation of indirect immunofluorescent tests in diagnostic immunology. The objective of the present study was to evaluate the performance of the NOVA View® system for the measurement of anti-dsDNA antibodies using the Crithidia luciliae indirect immunofluorescence test (CLIFT) technology.

METHODS

Analytical performance of NOVA View CLIFT was assessed in repeatability (within run) and reproducibility (between runs and instruments) studies. Two hundred-fifty patient samples (N=200 consecutive samples and N=50 samples from systemic lupus erythematosus patients) were tested to evaluate the agreement between results generated with NOVA View CLIFT, and those obtained with manual microscopic reading of the same slides. Positivity rate in SLE was assessed on the 50 SLE samples.

RESULTS

The NOVA View system showed high level of repeatability and reproducibility within runs, between runs, and between instruments. Agreement of NOVA View software interpretation and digital image reading results with manual microscopic reading results was 96.0%, and the same positivity rate was obtained on SLE samples by NOVA View digital image reading as that of manual microscopic reading (36.0% vs. 38.0%, respectively).

CONCLUSION

Results generated by NOVA View CLIFT were equivalent to those obtained by manual microscopic reading on a large routine sample set. NOVA View demonstrated consistency within and between runs, and between instruments. Automation of CLIFT provides reliability and is a suitable alternative for routine clinical laboratories.

摘要

引言

NOVA View是一种计算机辅助荧光显微镜,用于诊断免疫学中间接免疫荧光试验的自动读取和解释。本研究的目的是使用利什曼原虫间接免疫荧光试验(CLIFT)技术评估NOVA View®系统检测抗双链DNA抗体的性能。

方法

在重复性(批内)和再现性(批间和仪器间)研究中评估NOVA View CLIFT的分析性能。检测了250份患者样本(N = 200份连续样本和N = 50份系统性红斑狼疮患者样本),以评估NOVA View CLIFT产生的结果与同一玻片手动显微镜读数结果之间的一致性。对50份SLE样本评估SLE中的阳性率。

结果

NOVA View系统在批内、批间和仪器间均显示出高水平的重复性和再现性。NOVA View软件解释和数字图像读数结果与手动显微镜读数结果的一致性为96.0%,NOVA View数字图像读数在SLE样本上获得的阳性率与手动显微镜读数相同(分别为36.0%对38.0%)。

结论

在大量常规样本集上,NOVA View CLIFT产生的结果与手动显微镜读数获得的结果相当。NOVA View在批内、批间以及仪器间均表现出一致性。CLIFT的自动化提供了可靠性,是常规临床实验室的合适替代方法。