Inova Diagnostics Inc., San Diego, CA, USA.
Exagen Diagnostics, Vista, CA, USA.
J Immunol Res. 2017;2017:1720902. doi: 10.1155/2017/1720902. Epub 2017 Dec 31.
We sought to evaluate different anti-double-stranded DNA assays for their performance characteristics in monitoring disease activity fluctuations in systemic lupus erythematosus (SLE).
36 active SLE patients were followed monthly. At each study visit (total = 371), blood was collected and disease activity was scored using the SELENA-SLEDAI (excluding anti-dsDNA or complement components) and by a physician's global assessment (PGA). Four anti-dsDNA tests were compared. Linear mixed-effects models with random intercept and fixed slopes were used to evaluate the relationship between the longitudinal fluctuations of disease activity and anti-dsDNA titers.
At enrollment, positivity for QUANTA Lite and high-avidity anti-dsDNA assay was both 64% and significantly lower than anti-dsDNA positivity by QUANTA Flash (83%) and CLIFT (96%). Linear mixed-effects modeling indicated that the change in clinical SELENA-SLEDAI scores was associated with the titers of all anti-dsDNA with QUANTA Flash yielding the highest marginal (0.15; < 0.01). QUANTA Flash was the only anti-dsDNA assay significantly associated with the change in PGA (marginal = 0.05; < 0.01).
These data indicate that anti-dsDNA antibodies determined by QUANTA Flash have a value in monitoring SLE disease activity.
我们旨在评估不同的抗双链 DNA 检测方法在监测系统性红斑狼疮(SLE)疾病活动波动中的性能特征。
36 例活动性 SLE 患者每月随访。在每次研究就诊时(共 371 次)采集血液,并使用 SELENA-SLEDAI(不包括抗 dsDNA 或补体成分)和医生的总体评估(PGA)进行疾病活动评分。比较了四种抗 dsDNA 检测方法。采用具有随机截距和固定斜率的线性混合效应模型来评估疾病活动的纵向波动与抗 dsDNA 滴度之间的关系。
在入组时,QUANTA Lite 和高亲和力抗 dsDNA 检测的阳性率均为 64%,明显低于 QUANTA Flash(83%)和 CLIFT(96%)的抗 dsDNA 阳性率。线性混合效应模型表明,临床 SELENA-SLEDAI 评分的变化与所有抗 dsDNA 滴度相关,QUANTA Flash 的边际变化最大(0.15;<0.01)。QUANTA Flash 是唯一与 PGA 变化显著相关的抗 dsDNA 检测方法(边际变化=0.05;<0.01)。
这些数据表明,QUANTA Flash 测定的抗 dsDNA 抗体在监测 SLE 疾病活动方面具有价值。