Li Xin, Kaattari Stephen L, Vogelbein Mary A, Vadas George G, Unger Michael A
Department of Aquatic Health Sciences, Virginia Institute of Marine Science, College of William & Mary, Gloucester Point, VA 23062.
Sens Biosensing Res. 2016 Mar 1;7:115-120. doi: 10.1016/j.sbsr.2016.02.003.
Immunoassays based on monoclonal antibodies (mAbs) are highly sensitive for the detection of polycyclic aromatic hydrocarbons (PAHs) and can be employed to determine concentrations in near real-time. A sensitive generic mAb against PAHs, named as 2G8, was developed by a three-step screening procedure. It exhibited nearly uniformly high sensitivity against 3-ring to 5-ring unsubstituted PAHs and their common environmental methylated PAHs, with IC values between 1.68-31 μg/L (ppb). 2G8 has been successfully applied on the KinExA Inline Biosensor system for quantifying 3-5 ring PAHs in aqueous environmental samples. PAHs were detected at a concentration as low as 0.2 μg/L. Furthermore, the analyses only required 10 min for each sample. To evaluate the accuracy of the 2G8-based biosensor, the total PAH concentrations in a series of environmental samples analyzed by biosensor and GC-MS were compared. In most cases, the results yielded a good correlation between methods. This indicates that generic antibody 2G8 based biosensor possesses significant promise for a low cost, rapid method for PAH determination in aqueous samples.
基于单克隆抗体(mAb)的免疫测定法对多环芳烃(PAH)的检测具有高度敏感性,可用于近乎实时地测定其浓度。通过三步筛选程序开发出了一种针对PAH的敏感通用单克隆抗体,命名为2G8。它对三环至五环未取代的PAH及其常见的环境甲基化PAH表现出几乎一致的高灵敏度,IC值在1.68 - 31μg/L(ppb)之间。2G8已成功应用于KinExA在线生物传感器系统,用于定量分析水性环境样品中的三环至五环PAH。检测到的PAH浓度低至0.2μg/L。此外,每个样品的分析仅需10分钟。为评估基于2G8的生物传感器的准确性,对生物传感器和气相色谱 - 质谱联用仪(GC - MS)分析的一系列环境样品中的总PAH浓度进行了比较。在大多数情况下,两种方法的结果具有良好的相关性。这表明基于通用抗体2G8的生物传感器在低成本、快速测定水性样品中PAH方面具有巨大潜力。