Screw Joint Stability in Conventional and Abutment-Free Implant-Supported Fixed Restorations.

作者信息

Scherg Stefan, Karl Matthias

出版信息

Int J Prosthodont. 2016 Mar-Apr;29(2):142-6. doi: 10.11607/ijp.4458.

DOI:10.11607/ijp.4458
PMID:26929952
Abstract

PURPOSE

Procera Implant Bridges (PIBs) do not engage supporting implant shoulders and are fixed using comparably long retention screws. The aim of this in vitro clinical study was to determine the detorque values in PIBs and conventionally fabricated fixed dental prostheses (FDPs).

MATERIALS AND METHODS

Two groups of screw-retained implant-supported three-unit FDPs (n=10) were fabricated by means of conventional casting or computer-aided design/computer-assisted manufacture to fit an in vitro situation with two implants. Following fixation, the restorations were subjected to masticatory simulation (100,000 cycles, 100 N) and subsequent detorquing of the retention screws. In the clinical part, a total of 10 patients received PIB restorations in the premolar/molar region that were detorqued after 2, 4, and 6 months. One-sample t tests adjusted for multiple testing by the Bonferroni-Holm method were applied for statistical analysis based on percentage detorque values (α=.05).

RESULTS

60% of the initial torque values were maintained in screws directly retaining restorations, while the abutment screws used in the conventional restorations showed detorque levels in the range of 80%. No significant difference in detorque levels between screws retaining PIBs and conventional FDPs could be detected (P=.5186). The abutment screws showed significantly greater detorque values compared with screws directly retaining restorations (P=.0002; P=.0000). In vivo, a significant increase in detorque values ranging from 21.64 Ncm after 2 months to 27.81 Ncm after 6 months was recorded.

CONCLUSION

Prosthetic screws retaining implant-supported FDPs show torque loss during the initial period of service. Retightening reduces the amount of future torque loss.

摘要

相似文献

1
Screw Joint Stability in Conventional and Abutment-Free Implant-Supported Fixed Restorations.
Int J Prosthodont. 2016 Mar-Apr;29(2):142-6. doi: 10.11607/ijp.4458.
2
Strain development of screw-retained implant-supported fixed restorations: procera implant bridge versus conventionally cast restorations.螺钉固位式种植体支持固定修复体的应变发展:Procera 种植体桥与传统铸造修复体的比较。
Int J Prosthodont. 2012 Mar-Apr;25(2):166-9.
3
In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.体外评估螺丝固位和粘结固位种植体固定修复体基台螺丝的反向扭矩值和边缘间隙。
Int J Oral Maxillofac Implants. 2009 Nov-Dec;24(6):1061-7.
4
In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after cyclic loading.循环加载后全牙弓下颌种植体支持固定义齿基台螺钉的体外力学分析
J Prosthet Dent. 2015 May;113(5):432-9. doi: 10.1016/j.prosdent.2014.09.026. Epub 2015 Feb 11.
5
Effect of engaging abutment position in implant-borne, screw-retained three-unit fixed cantilevered prostheses.种植体支持的螺丝固位三单位固定桥修复中基台位置的影响。
J Prosthodont. 2011 Jul;20(5):348-54. doi: 10.1111/j.1532-849X.2011.00714.x. Epub 2011 May 17.
6
Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants.采用莫氏锥度种植体评估基台和柱螺钉的扭矩保持情况。
J Craniofac Surg. 2012 Nov;23(6):e631-4. doi: 10.1097/SCS.0b013e318270fe0e.
7
Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks.CAD-CAM与覆盖式3单位种植体支持框架的边缘适合性及光弹性应力分析
J Prosthet Dent. 2017 Mar;117(3):373-379. doi: 10.1016/j.prosdent.2016.06.011. Epub 2016 Sep 22.
8
Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns.基牙类型和美学贴面修复对种植支持式冠桥基台螺丝预紧力维持的影响。
J Prosthodont. 2014 Feb;23(2):134-9. doi: 10.1111/jopr.12065. Epub 2013 May 31.
9
Effect of different maintenance time of torque application on detorque values of abutment screws in full-arch implant-supported fixed prostheses.不同扭矩维持时间对全口种植体支持固定修复体基台螺丝扭力值的影响。
Clin Implant Dent Relat Res. 2018 Oct;20(5):848-851. doi: 10.1111/cid.12657. Epub 2018 Aug 15.
10
The effects of loading on the preload and dimensions of the abutment screw for a 3-unit cantilever-fixed prosthesis design.加载对 3 单位悬臂固定修复体设计的基台螺丝的预紧力和尺寸的影响。
Implant Dent. 2013 Aug;22(4):414-21. doi: 10.1097/ID.0b013e31829c227a.

引用本文的文献

1
Cad-cam procedure and implant-prosthetic rehaBilitation. Case report.计算机辅助设计与制造程序及种植体-修复体康复。病例报告。
Oral Implantol (Rome). 2016 Nov 13;9(1):27-32. doi: 10.11138/orl/2016.9.1.027. eCollection 2016 Jan-Mar.