Mohammed Hnd Hadi, Lee Jin-Han, Bae Ji-Myung, Cho Hye-Won
Department of Prosthodontics, College of Dentistry, Wonkwang University, Iksan, Republic of Korea.
Department of Dental Biomaterials, College of Dentistry, Wonkwang University, Iksan, Republic of Korea.
J Adv Prosthodont. 2016 Feb;8(1):62-9. doi: 10.4047/jap.2016.8.1.62. Epub 2016 Feb 23.
The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants.
Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests.
The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05).
Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.
本研究旨在评估基台螺丝长度和循环加载对外六角(EH)和内六角(IH)种植体拆除扭矩(RTV)的影响。
40颗螺丝固位单冠连接到外六角和内六角种植体上。将制备好的钛基台螺丝根据螺纹数量分为8组(每组n = 5):外六角12.5、6.5、3.5、2.5螺纹组和内六角6.5、5、3.5、2.5螺纹组。基台螺丝以20 Ncm扭矩分两次拧紧,间隔10分钟。5分钟后,用数字扭矩计(MGT12)测量基台螺丝的初始拆除扭矩。构建一个定制夹具,在上颌第一磨牙中央窝沿种植体长轴施加负载。在以1 Hz频率施加50 N的机械负载16000次循环后,测量加载后的拆除扭矩。统计分析包括单因素方差分析和配对t检验。
外六角2.5螺纹组和内六角2.5螺纹组的加载后拆除扭矩显著低于初始拆除扭矩(P <.05)。8组之间的初始拆除扭矩无显著差异,而外六角6.5和外六角3.5螺纹组的加载后拆除扭矩高于内六角3.5螺纹组(P <.05)。
在本研究的局限性内,循环加载后,螺丝长度较短的外六角种植体在扭矩维持方面比螺丝长度较短的内六角种植体更具优势。