Lee Joo-Hee, Cha Hyun-Suk
Department of Prosthodontics, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Republic of Korea.
J Adv Prosthodont. 2018 Dec;10(6):415-421. doi: 10.4047/jap.2018.10.6.415. Epub 2018 Dec 19.
This study investigated the effects of abutment screw lengths on screw loosening and removal torque in external connection implants after oblique cyclic loading.
External connection implants were secured with abutment screws to straight abutments. The abutment-implant assemblies were classified into seven groups based on the abutment screw length, with each group consisting of five assemblies. A cyclic load of 300 N was applied at a 30° angle to the loading axis until one million cycles were achieved. Removal torque values (RTVs) before and after loading, and RTV differences were evaluated. The measured values were analyzed using repeated measures of analysis of variance with the Student-Newman-Keuls multiple comparisons.
All assemblies survived the oblique cyclic loading test without screw loosening. There was a significant decrease in the RTVs throughout the observed abutment screw lengths when the abutment-implant assemblies were loaded repeatedly (<.001). However, the abutment screw length did not show significant difference on the RTVs before and after the experiment when the abutment screw length ranged from 1.4 to 3.8 mm (=.647).
Within the limit of this experiment, our results indicate that the abutment screw length did not significantly affect RTV differences after oblique cyclic loading when a minimum length of 1.4 mm (3.5 threads) was engaged. These findings suggest that short abutment screws may yield stable clinical outcomes comparable to long screws in terms of load resistance.
本研究调查了倾斜循环加载后,基台螺钉长度对外连接种植体螺钉松动及拆除扭矩的影响。
使用基台螺钉将外连接种植体固定于直基台上。根据基台螺钉长度,将基台-种植体组件分为七组,每组包含五个组件。以30°角向加载轴施加300 N的循环载荷,直至达到100万次循环。评估加载前后的拆除扭矩值(RTV)以及RTV差值。采用重复测量方差分析及Student-Newman-Keuls多重比较对测量值进行分析。
所有组件均通过倾斜循环加载试验,未出现螺钉松动。当对基台-种植体组件进行反复加载时,在观察到的所有基台螺钉长度范围内,RTV均显著降低(<.001)。然而,当基台螺钉长度在1.4至3.8 mm之间时,实验前后的RTV在基台螺钉长度方面未显示出显著差异(=.647)。
在本实验范围内,我们的结果表明,当最少长度为1.4 mm(3.5个螺纹)时,倾斜循环加载后基台螺钉长度对RTV差值无显著影响。这些发现表明,就抗载荷能力而言,短基台螺钉可能产生与长螺钉相当的稳定临床效果。