非骨水泥型股骨柄三种主要设计的术后假体周围骨密度变化差异:一项3年随访研究

Difference in Postoperative Periprosthetic Bone Mineral Density Changes Between 3 Major Designs of Uncemented Stems: A 3-Year Follow-Up Study.

作者信息

Inaba Yutaka, Kobayashi Naomi, Oba Masatoshi, Ike Hiroyuki, Kubota So, Saito Tomoyuki

机构信息

Department of Orthopaedic Surgery, Yokohama City University, Yokohama, Japan.

出版信息

J Arthroplasty. 2016 Aug;31(8):1836-41. doi: 10.1016/j.arth.2016.02.009. Epub 2016 Feb 8.

Abstract

BACKGROUND

Although few studies have examined the direct effect of stress shielding on clinical outcomes, periprosthetic bone loss due to stress shielding is still an issue of concern, especially when physicians perform uncemented total hip arthroplasty (THA) in younger patients. Differences in femoral stem design may affect the degree of postoperative stress shielding. Therefore, the characteristics of the behavior for stress shielding of each type of femoral stem should be determined. This study compares differences in bone mineral density (BMD) change in the femur after primary THA between 3 major types of uncemented stems.

METHODS

Among a total of 89 hips, 26 hips received THA with a fit-and-fill type stem (VerSys Fiber Metal MidCoat; Zimmer, Inc, Warsaw, IN), 32 hips received a tapered rectangular Zweymüller-type stem (SL-Plus; Smith & Nephew Inc, Memphis, TN), and 31 received a tapered wedge-type stem (Accolade TMZF; Stryker Orthopaedics, Mahwah, NJ). BMD measurements were performed with a HOLOGIC Discovery device (Hologic Inc, Waltham, MA).

RESULTS

BMD in the medial-proximal femur was maintained for 3 years after THA in the group with the tapered wedge-type stem. BMD in the lateral-proximal femur was maintained for 3 years after THA in the group with the Zweymüller-type stem. There were no significant differences in the Harris Hip Score among the 3 stem groups preoperatively and 1, 2, and 3 years after surgery.

CONCLUSION

There are clear differences in postoperative BMD loss of the proximal femur among these 3 commonly used uncemented stems.

摘要

背景

尽管很少有研究探讨应力遮挡对临床结果的直接影响,但应力遮挡导致的假体周围骨丢失仍是一个值得关注的问题,尤其是当医生为年轻患者进行非骨水泥型全髋关节置换术(THA)时。股骨柄设计的差异可能会影响术后应力遮挡的程度。因此,应确定每种类型股骨柄的应力遮挡行为特征。本研究比较了3种主要类型的非骨水泥柄初次全髋关节置换术后股骨骨密度(BMD)变化的差异。

方法

在总共89例髋关节中,26例接受了适配填充型柄(VerSys Fiber Metal MidCoat;Zimmer公司,印第安纳州华沙)的全髋关节置换术,32例接受了锥形矩形Zweymüller型柄(SL-Plus;史赛克公司,田纳西州孟菲斯)的全髋关节置换术,31例接受了锥形楔形柄(Accolade TMZF;Stryker Orthopaedics公司,新泽西州马霍瓦)的全髋关节置换术。使用HOLOGIC Discovery设备(Hologic公司,马萨诸塞州沃尔瑟姆)进行骨密度测量。

结果

锥形楔形柄组全髋关节置换术后3年股骨近端内侧骨密度保持稳定。Zweymüller型柄组全髋关节置换术后3年股骨近端外侧骨密度保持稳定。3组柄术前及术后1年、2年和3年的Harris髋关节评分无显著差异。

结论

这3种常用的非骨水泥柄术后股骨近端骨密度丢失存在明显差异。