Çiçek Ersan, Akkocan Oguzhan, Furuncuoglu Fatma
Department of Endodontics, Faculty of Dentistry, Bülent Ecevit University, Zonguldak, Turkey.
Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey.
J Conserv Dent. 2016 Jan-Feb;19(1):68-71. doi: 10.4103/0972-0707.173203.
BACKGROUND/AIM: To compare apically extruded debris using ProTaper Universal (PTU), ProTaper Next (PTN), WaveOne (WO), Twisted File (TF), M-Two (MT), and Revo-S (RS) after determining the working length (WL) with root ZX.
Seventy-two teeth were selected. The WL determination was performed with root ZX. The teeth were divided into six experimental groups, randomly. In groups, root canals were prepared with PTU to size F4/0.06, with PTN to size X4/0.06, with WO to size 40/0.08, with TF to size 40/0.04, with MT to size 40/0.06, and with RS to size AS40/0.06. After preparations were completed, final irrigation was performed with 2 mL distilled water, and a total of 10 mL of distilled water was used in each tooth. Tubes were stored in an incubator at 68°C for 5 days to evaporate the distilled water before weighing the dry debris. Data were analyzed by the Mann-Whitney U-test.
The RS group led to the highest amount of extruded debris, however, WO led to the least amount of extruded debris. There was no statistically difference among the groups (P > 0.05).
The authors conclude that the results obtained might depend on the apex locator used to determine the WL.
背景/目的:在用Root ZX确定工作长度(WL)后,比较使用ProTaper Universal(PTU)、ProTaper Next(PTN)、WaveOne(WO)、Twisted File(TF)、M-Two(MT)和Revo-S(RS)时根尖挤出碎屑的情况。
选取72颗牙齿。使用Root ZX确定工作长度。将牙齿随机分为六个实验组。在各实验组中,分别用PTU预备根管至F4/0.06规格,用PTN预备至X4/0.06规格,用WO预备至40/0.08规格,用TF预备至40/0.04规格,用MT预备至40/0.06规格,用RS预备至AS40/0.06规格。预备完成后,用2 mL蒸馏水进行最终冲洗,每颗牙齿总共使用10 mL蒸馏水。将根管置于68°C的培养箱中5天以蒸发蒸馏水,然后对干燥的碎屑进行称重。数据采用Mann-Whitney U检验进行分析。
RS组挤出的碎屑量最多,然而,WO组挤出的碎屑量最少。各组之间无统计学差异(P>0.05)。
作者得出结论,所获得的结果可能取决于用于确定工作长度的根尖定位仪。