Suppr超能文献

不同单根管器械系统(Reciproc、F360、OneShape与Mtwo)根尖部推出碎屑的定量评估

Quantitative evaluation of apically extruded debris with different single-file systems: Reciproc, F360 and OneShape versus Mtwo.

作者信息

Bürklein S, Benten S, Schäfer E

机构信息

Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, Münster, Germany.

出版信息

Int Endod J. 2014 May;47(5):405-9. doi: 10.1111/iej.12161. Epub 2013 Jul 26.

Abstract

AIM

To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system.

METHODOLOGY

Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded.

RESULTS

Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05).

CONCLUSIONS

Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation.

摘要

目的

在实验室环境下,评估与不同单根镍钛器械系统相比,一种多根旋转器械系统所产生的根尖部挤出碎屑的量。

方法

80颗人下颌中切牙随机分为四组(每组20颗牙)。按照制造商的说明,使用往复式单根器械系统Reciproc、单根旋转器械系统F360和OneShape以及多根旋转器械Mtwo对根管进行预备。将根尖部挤出的碎屑收集起来,在预先称重的玻璃瓶中干燥。用微量天平评估碎屑的量,并使用方差分析和事后Student-Newman-Keuls检验进行统计学分析。还记录了使用不同器械预备根管所需的时间。

结果

与所有其他系统相比,Reciproc产生的碎屑明显更多(P < 0.05)。在两个单根旋转系统和多根旋转系统之间未观察到显著差异(P > 0.05)。使用三种单根系统进行根管预备明显比使用Mtwo更快(P < 0.05)。

结论

在本研究条件下,所有系统均导致根尖部碎屑挤出。与往复式器械相比,旋转器械预备与较少的碎屑挤出相关。