使用标准化胰腺组织学评估对60只猫进行血清特异性fPL(™)和1,2 - 二 - 月桂酰 - 消旋甘油 - 3 - 戊二酸 - (6'-甲基试卤灵)酯检测的比较

Comparison of Serum Spec fPL(™) and 1,2-o-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6'-Methylresorufin) Ester Assay in 60 Cats Using Standardized Assessment of Pancreatic Histology.

作者信息

Oppliger S, Hilbe M, Hartnack S, Zini E, Reusch C E, Kook P H

机构信息

Clinic for Small Animal Internal Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.

Institute for Veterinary Pathology, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.

出版信息

J Vet Intern Med. 2016 May;30(3):764-70. doi: 10.1111/jvim.13924. Epub 2016 Mar 10.

Abstract

BACKGROUND

Feline pancreas-specific lipase (Spec fPL) is considered a useful test for the antemortem diagnosis of pancreatitis in cats. A recent study found good agreement between the results of the Spec fPL and catalytic 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay. Prospective studies evaluating their sensitivity and specificity are lacking.

OBJECTIVES

To compare the results of the Spec fPL and the DGGR assays with a standardized histologic assessment of the pancreas.

ANIMALS

Sixty client-owned cats presented for necropsy.

PROSPECTIVE STUDY

Spec fPL concentrations and serum DGGR lipase activity were measured from the same blood sample. The pancreas was removed within 3 hours after euthanasia; serial transverse sections were made every 0.5 cm throughout the entire pancreas and reviewed using a histologic grading scheme. Sensitivity and specificity for the Spec fPL and DGGR assay results were determined.

RESULTS

The sensitivity and specificity for the Spec fPL assay (cutoff value ≥5.4 μg/L) was 42.1 [95% confidence interval (95% CI), 29.4-55.9%] and 100% (95% CI, 31.0-100.0%). The sensitivity and specificity for the DGGR assay (cutoff value >26 U/L) was 36.8 (95% CI, 24.7-50.7%) and 100% (95% CI, 31.0-100.0%). When lymphocytic inflammation up to 10% of a section was considered normal, the sensitivity and specificity for Spec fPL assay (cutoff value ≥5.4 μg/L) was 61.1 (95% CI, 36.1-81.7%) and 69.0% (95% CI, 52.8-81.9%) and the sensitivity and specificity for the DGGR assay (cutoff value >26 U/L) was 66.7 (95% CI, 41.2-85.6%) and 78.6% (95% CI, 62.8-89.2%).

CONCLUSIONS AND CLINICAL IMPORTANCE

Both lipase assays performed similarly well, but their agreement with histologic pancreatic inflammation was limited.

摘要

背景

猫胰腺特异性脂肪酶(Spec fPL)被认为是猫胰腺炎生前诊断的一项有用检测指标。最近一项研究发现,Spec fPL检测结果与催化型1,2 - O - 二月桂酰 - rac - 甘油 - 3 - 戊二酸 -(6'-甲基试卤灵)酯(DGGR)脂肪酶检测结果具有良好的一致性。目前缺乏评估它们敏感性和特异性的前瞻性研究。

目的

将Spec fPL和DGGR检测结果与胰腺的标准化组织学评估进行比较。

动物

60只由客户拥有并送来进行尸检的猫。

前瞻性研究

从同一血样中检测Spec fPL浓度和血清DGGR脂肪酶活性。安乐死后3小时内取出胰腺;在整个胰腺上每隔0.5厘米制作连续的横切片,并使用组织学分级方案进行检查。确定Spec fPL和DGGR检测结果的敏感性和特异性。

结果

Spec fPL检测(临界值≥5.4μg/L)的敏感性和特异性分别为42.1 [95%置信区间(95%CI),29.4 - 55.9%]和100%(95%CI,31.0 - 100.0%)。DGGR检测(临界值>26U/L)的敏感性和特异性分别为36.8(95%CI,24.7 - 50.7%)和100%(95%CI,31.0 - 100.0%)。当将切片中高达10%的淋巴细胞性炎症视为正常时,Spec fPL检测(临界值≥5.4μg/L)的敏感性和特异性分别为61.1(95%CI;36.1 - 81.7%)和69.0%(95%CI,52.8 - 81.9%),DGGR检测(临界值>26U/L)的敏感性和特异性分别为66.7(95%CI,41.2 - 85.6%)和78.6%(95%CI,62.8 - 89.2%)。

结论及临床意义

两种脂肪酶检测表现相似,但它们与胰腺组织学炎症的一致性有限。