CdSe/ZnS 量子点标记侧向流条用于快速定量检测胃癌相关抗原 72-4。

CdSe/ZnS Quantum Dot-Labeled Lateral Flow Strips for Rapid and Quantitative Detection of Gastric Cancer Carbohydrate Antigen 72-4.

机构信息

Out-Patient Department, Zhujiang Hospital, Southern Medical University, 253 Gongye Road, 510280, Guangzhou, Guangdong, People's Republic of China.

Institute of Nano Biomedical and Engineering, Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, 200240, Shanghai, People's Republic of China.

出版信息

Nanoscale Res Lett. 2016 Dec;11(1):138. doi: 10.1186/s11671-016-1355-3. Epub 2016 Mar 11.

Abstract

Carbohydrate antigen 72-4 (CA72-4) is an important biomarker associated closely with diagnosis and prognosis of early gastric cancer. How to realize quick, sensitive, specific, and quantitative detection of CA72-4 in clinical specimens has become a great requirement. Herein, we reported a CdSe/ZnS quantum dot-labeled lateral flow test strip combined with a charge-coupled device (CCD)-based reader was developed for rapid, sensitive, and quantitative detection of CA72-4. Two mouse monoclonal antibodies (mAbs) against CA72-4 were employed. One of them was coated as a test line, while another mAb was labeled with quantum dots and coated onto conjugate pad. The goat anti-mouse IgG was immobilized as a control line. After sample was added, a sandwich structure was formed with CA72-4 and these two mAbs. The fluorescent signal from quantum dots (QD)-labeled mAb in sandwich structure was related to the amount of detected CA72-4. A CCD-based reader was used to realize quantitative detection of CA72-4. Results showed that developed QD-labeled lateral flow strips to detect CA72-4 biomarker with the sensitivity of 2 IU/mL and 10 min detection time. One hundred sera samples from clinical patients with gastric cancer and healthy people were used to confirm specificity of this strip method; results showed that established strip method own 100 % reproducibility and 100 % specificity compared with Roche electrochemiluminescence assay results. In conclusion, CdSe/ZnS quantum dot-labeled lateral flow strips for detection of CA72-4 could realize rapid, sensitive, and specific detection of clinical samples and could own great potential in clinical translation in near future.

摘要

糖类抗原 72-4(CA72-4)是与早期胃癌的诊断和预后密切相关的重要生物标志物。如何在临床标本中实现 CA72-4 的快速、灵敏、特异和定量检测已成为巨大的需求。在此,我们报道了一种基于 CdSe/ZnS 量子点标记的侧向流动测试条与电荷耦合器件(CCD)- 基于读取器的快速、灵敏和定量检测 CA72-4 的方法。使用了两种针对 CA72-4 的单克隆抗体(mAb)。其中一种被涂覆为测试线,而另一种 mAb 被标记量子点并涂覆在结合垫上。山羊抗小鼠 IgG 被固定为控制线。加入样品后,CA72-4 和这两种 mAb 形成三明治结构。夹心结构中量子点(QD)标记 mAb 的荧光信号与检测到的 CA72-4 的量有关。使用 CCD 基于读取器实现 CA72-4 的定量检测。结果表明,开发的 QD 标记侧向流动条可检测 CA72-4 生物标志物,灵敏度为 2 IU/mL,检测时间为 10 分钟。使用来自临床胃癌患者和健康人的 100 个血清样本证实了该条带方法的特异性;结果表明,与罗氏电化学发光测定结果相比,建立的条带方法具有 100%的重现性和 100%的特异性。总之,用于检测 CA72-4 的 CdSe/ZnS 量子点标记的侧向流动条能够实现对临床样本的快速、灵敏和特异检测,在不久的将来具有很大的临床转化潜力。