Suppr超能文献

Aortic dissection: review of value and limitations of two-dimensional echocardiography in a six-year experience.

作者信息

Khandheria B K, Tajik A J, Taylor C L, Safford R E, Miller F A, Stanson A W, Sinak L J, Oh J K, Seward J B

机构信息

Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN 55905.

出版信息

J Am Soc Echocardiogr. 1989 Jan-Feb;2(1):17-24. doi: 10.1016/s0894-7317(89)80025-2.

Abstract

The utility of transthoracic two-dimensional echocardiography in patients with aortic dissection was assessed by retrospective analysis in 67 patients: 31 patients with DeBakey type I, 21 patients with type II, 10 patients with type III, and five patients with false-positive diagnoses. Aortic dissection was correctly identified by two-dimensional echocardiography in 49 patients; 13 had false-negative diagnoses. Therefore the sensitivity was 79%, and the positive predictive accuracy was 91%. Transthoracic two-dimensional echocardiography is a reasonable screening technique for diagnosis of aortic dissection.