Jedrzejewski T, Sokołowski J, Połać B
Protet Stomatol. 1989 Jul-Dec;39(4-6):202-8.
The authors measured the effect of the convergence angle of the ground tooth on the fastening of cast crowns. The study was carried out on phantom models of teeth made of stainless steel with abutement convergence angles from 1 to 10 degrees. The force of the connection was measured using the Instron testing device. The avulsing force acted along the long axis of the abutement. Additionally the fixing force of phosphate, polycarboxylate and ionomer-glass was compared. A fall of the force of crown fastening was observed with increasing value of the convergence angle of the abutement, especially for phosphorus and ionomer-glass cement. The crowns fastened with polycarboxylate cement showed a threefold smaller fall of the fastening force with increasing value of the convergence angle of the abutement.
作者测量了基牙聚合角对铸造冠固位的影响。该研究在由不锈钢制成的牙齿模型上进行,基牙聚合角为1至10度。使用英斯特朗测试设备测量连接力。拔除力沿基牙长轴方向作用。此外,还比较了磷酸盐、聚羧酸酯和玻璃离子水门汀的固位力。随着基牙聚合角增大,观察到冠固位力下降,尤其是对于磷酸锌水门汀和玻璃离子水门汀。用聚羧酸酯水门汀固定的冠,随着基牙聚合角增大,固位力下降幅度小三倍。