Suppr超能文献

Detection of osteomyelitis at fracture nonunion sites: comparison of two scintigraphic methods.

作者信息

Seabold J E, Nepola J V, Conrad G R, Marsh J L, Montgomery W J, Bricker J A, Kirchner P T

机构信息

Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City 52242.

出版信息

AJR Am J Roentgenol. 1989 May;152(5):1021-7. doi: 10.2214/ajr.152.5.1021.

Abstract

Forty-nine patients with 50 fracture nonunions 4-48 months after injury underwent technetium-99m methylene diphosphonate (99mTc-MDP) scintigraphy on day 1, combined 99mTc-MDP and indium-111 leukocyte (111In-WBC) scintigraphy on day 2, and gallium-67 (67Ga) scintigraphy on day 3. The results were compared to evaluate the relative abilities of these scintigraphic techniques to detect osteomyelitis. Nine patients had clinical evidence of infection at the time of imaging, and 40 patients (41 fractures) did not. Open-biopsy cultures were performed at all fracture sites and were positive at 21 (42%) of the 50 sites. Combined 99mTc-MDP/111In-WBC images were interpreted with the use of two criteria. A positive study by the first criterion required 111In-WBC localization in the region of the nonunion fracture. A positive study by the second criterion required 111In-WBC localization in bone at the fracture site. The first criterion yielded a sensitivity of 84%, specificity of 72%, and accuracy of 74%; the specificity improved to 97% with an accuracy of 88% when the second criterion was used. Ten (25%) of the 40 patients thought not to have osteomyelitis by clinical criteria at the time of imaging had true-positive 99mTc-MDP/111In-WBC studies by biopsy culture results. Gallium-67 studies were interpreted as nondiagnostic if localization of radioisotope at fracture sites was equal to that with 99mTc-MDP, positive if 67Ga localization was greater than that of 99mTc-MDP, and negative if it was less than that of 99mTc-MDP. Twenty-one 67Ga studies were interpreted as nondiagnostic; 11 (52%) of the 21 had culture-positive fracture sites. The accuracy of 67Ga/99mTc-MDP imaging was 39%. Combined 99mTc-MDP/111In-WBC imaging is useful in the detection of osteomyelitis at fracture nonunion sites and improves the specificity of 111In-WBC imaging by differentiating inflammation/infection in adjacent soft tissue from osteomyelitis at the fracture site. Gallium-67 with 99mTc-MDP imaging is not sufficiently reliable in this clinical setting to be useful as an indicator for osteomyelitis.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验