Suppr超能文献

一项关于眼眶超声检查和锥形束计算机断层扫描(CBCT)对疑似眼眶底骨折患者诊断效能的对比研究。

A comparable study of the diagnostic performance of orbital ultrasonography and CBCT in patients with suspected orbital floor fractures.

作者信息

Johari Masoumeh, Ghavimi Mohammad Ali, Mahmoudian Hediyeh, Javadrashid Reza, Mirakhor Samani Simin, Fouladi Daniel F

机构信息

1 Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran.

2 Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran.

出版信息

Dentomaxillofac Radiol. 2016 Jul;45(6):20150311. doi: 10.1259/dmfr.20150311. Epub 2016 May 4.

Abstract

OBJECTIVES

: To compare the diagnostic performance of ultrasonography and CBCT against CT in detecting orbital floor fractures.

METHODS

: A total of 120 orbits with clinical suspicion of isolated orbital floor fractures underwent multislice CT scanning with coronal reconstruction; orbital ultrasonography using a standard machine equipped with a 7- to 10-MHz linear transducer; and CBCT. Patients with severe head and face injuries were not included. The diagnostic performance of ultrasonography and CBCT was reported assuming conventional CT as the imaging method of choice.

RESULTS

: According to CT findings, fractures of the floor were present in 39 orbits. The sensitivity, specificity, positive-predictive value and negative-predictive value of ultrasonography in detecting orbital floor fractures were 87.2%, 100%, 100% and 94.2%, respectively. The corresponding values for CBCT were 97.4%, 97.5%, 95.0%, and 98.8%, respectively. Areas under the receiver operator characteristics curves of orbital floor fracture detection were 0.94 for ultrasonography and 0.98 for CBCT.

CONCLUSIONS

: When conventional CT cannot be performed in patients with clinically suspected orbital floor fracture and no severe or complex head and face injuries, CBCT could be used in detecting fractures as a reliable surrogate. Because of a lower sensitivity of ultrasonography, however, its use is limited in this regard.

摘要

目的

比较超声检查和锥形束计算机断层扫描(CBCT)相对于计算机断层扫描(CT)在检测眶底骨折方面的诊断性能。

方法

对120例临床怀疑孤立性眶底骨折的眼眶进行多层CT扫描及冠状位重建;使用配备7至10MHz线性探头的标准机器进行眼眶超声检查;以及CBCT检查。排除严重头面部损伤的患者。以传统CT作为首选成像方法,报告超声检查和CBCT的诊断性能。

结果

根据CT检查结果,39个眼眶存在眶底骨折。超声检查检测眶底骨折的灵敏度、特异度、阳性预测值和阴性预测值分别为87.2%、100%、100%和94.2%。CBCT的相应值分别为97.4%、97.5%、95.0%和98.8%。超声检查和CBCT检测眶底骨折的受试者操作特征曲线下面积分别为0.94和0.98。

结论

对于临床怀疑眶底骨折且无严重或复杂头面部损伤的患者,若无法进行传统CT检查,CBCT可作为可靠替代方法用于检测骨折。然而,由于超声检查灵敏度较低,其在这方面的应用受到限制。

相似文献

引用本文的文献

2
[The use of fracture sonography in midface traumatology].[骨折超声检查在面中部创伤学中的应用]
HNO. 2025 Feb;73(2):152-162. doi: 10.1007/s00106-024-01541-9. Epub 2024 Dec 16.
4
Diagnostic Accuracy of Ultrasonography for the Assessment of Maxillofacial Fractures: A Meta-analysis.超声检查评估颌面骨折的诊断准确性:一项荟萃分析。
J Int Soc Prev Community Dent. 2021 Sep 21;11(5):503-509. doi: 10.4103/jispcd.JISPCD_201_21. eCollection 2021 Sep-Oct.

本文引用的文献

3
Patient radiation dose and protection from cone-beam computed tomography.患者辐射剂量与锥形束计算机断层扫描防护
Imaging Sci Dent. 2013 Jun;43(2):63-9. doi: 10.5624/isd.2013.43.2.63. Epub 2013 Jun 14.
4
Orbital trauma: keep an eye for the details!眼眶外伤:关注细节!
J Contemp Dent Pract. 2012 Mar 1;13(2):232-5. doi: 10.5005/jp-journals-10024-1128.
6
Orbital fractures: a review.眼眶骨折:综述
Clin Ophthalmol. 2011 Jan 12;5:95-100. doi: 10.2147/OPTH.S14972.
7
Blow-out fractures: patterns of ocular motility and effect of surgical repair.眼眶爆裂性骨折:眼球运动模式及手术修复效果
Br J Oral Maxillofac Surg. 2010 Jan;48(1):40-3. doi: 10.1016/j.bjoms.2009.04.028. Epub 2009 Aug 28.
10
Role of multidetector row computed tomography in the management of mandible traumatic lesions.
Semin Ultrasound CT MR. 2009 Jun;30(3):174-80. doi: 10.1053/j.sult.2009.02.008.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验