使用高效液相色谱法对给药装置中地西泮在聚氯乙烯(PVC)和非PVC材质导管上的吸附进行定量测定。

Diazepam sorption to PVC- and non-PVC-based tubes in administration sets with quantitative determination using a high-performance liquid chromatographic method.

作者信息

Jin Su-Eon, You Siwon, Jeon Seungho, Hwang Sung-Joo

机构信息

College of Pharmacy, Yonsei University, Incheon 21983, Republic of Korea; College of Medicine, Yonsei University, Seoul 03722, Republic of Korea; Yonsei Institute of Pharmaceutical Sciences, Incheon 21983, Republic of Korea.

College of Pharmacy, Yonsei University, Incheon 21983, Republic of Korea; Yonsei Institute of Pharmaceutical Sciences, Incheon 21983, Republic of Korea.

出版信息

Int J Pharm. 2016 Jun 15;506(1-2):414-9. doi: 10.1016/j.ijpharm.2016.04.040. Epub 2016 Apr 16.

Abstract

Diazepam is highly sorbed to the plastic materials of administration sets for intravenous infusion. This can be detrimental as it should be delivered to the patient at the administered amount for efficacy and safety. We report here the sorption levels of diazepam onto various types of tubes in administration sets. The tube materials of the administration sets included polyvinylchloride (PVC) and the non-PVC materials such as polyurethane (PU) and polyolefin (PO) were used. Two conditions of diazepam administered in preclinical and clinical settings were tested using an infusion pump. Injections were prepared by diluting diazepam to 20mg/500mL and 10mg/100mL in 5% dextrose. Diluted diazepam solutions at the concentrations of 10mg/100mL and 20mg/500mL were separately delivered through 1m of tubing at 1mL/min for 1.05 and 4.05h. Samples were analyzed using a high-performance liquid chromatography with UV detection. PVC- and PU-based tubes showed higher sorption of diazepam than did PO-based tubes. PO-based tubes delivered more than 90% of the administered diazepam. The results showed that PO-based tubes of administration sets have a promising potential to deliver hydrophobic drugs like diazepam with minimal sorption levels. In addition, the tube materials in administration sets may be one of the critical factors to ensure drug efficacy and safety.

摘要

地西泮高度吸附于静脉输液给药装置的塑料材料上。这可能是有害的,因为它应以给药量输送给患者以确保疗效和安全性。我们在此报告地西泮在给药装置中各种类型导管上的吸附水平。给药装置的导管材料包括聚氯乙烯(PVC),并使用了诸如聚氨酯(PU)和聚烯烃(PO)等非PVC材料。使用输液泵测试了在临床前和临床环境中给药的两种地西泮情况。通过在5%葡萄糖中将地西泮稀释至20mg/500mL和10mg/100mL来制备注射液。将浓度为10mg/100mL和20mg/500mL的稀释地西泮溶液分别以1mL/min的速度通过1m长的管路输送1.05和4.05小时。使用带紫外检测的高效液相色谱法分析样品。基于PVC和PU的导管显示出比基于PO的导管更高的地西泮吸附。基于PO的导管输送了超过90%的给药地西泮。结果表明,给药装置中基于PO的导管具有以最小吸附水平输送像地西泮这样的疏水药物的潜在前景。此外,给药装置中的导管材料可能是确保药物疗效和安全性的关键因素之一。